Guidelines are provided for Temporary Protective Grounding (TPG) of electric power lines to assist in protection of workers from voltages and currents that might develop at a de-energized worksite during maintenance of ac overhead and underground, transmission and distribution lines, cables, and equipment. Other forms of worker protection include isolation and insulation. These methods are described in other documents and guides and are not discussed here.
- Standard Committee
- PE/T&D - Transmission and Distribution
- Status
- Active Standard
- PAR Approval
- 2005-12-07
- Superseding
- 1048-2003
- Amendment
-
1048a-2021
- Proposed Amendment
-
P1048b
- Board Approval
- 2016-01-29
- History
-
- ANSI Approved:
- 2017-08-31
- Published:
- 2016-12-21
Working Group Details
- Society
- IEEE Power and Energy Society
- Standard Committee
- PE/T&D - Transmission and Distribution
- Working Group
-
ESMOL-1048_WG - Protective Grounding of Power Lines Working Group
- IEEE Program Manager
- Michael Kipness
Contact Michael Kipness - Working Group Chair
- Gary Zevenbergen
Other Activities From This Working Group
Current projects that have been authorized by the IEEE SA Standards Board to develop a standard.
P1048
Guide for Protective Grounding of Power Lines
This document provides guidelines for grounding methods to protect workers and the public from voltages that might develop in a jobsite during de-energized maintenance of overhead transmission and distribution lines.
P1048b
IEEE Draft Guide for Protective Grounding of Power Lines Amendment B: Differentiating the Fabric Carrier Mat and the Rigid Carrier Mat
Guidelines are provided for Temporary Protective Grounding (TPG) of electric power lines to assist in protection of workers from voltages and currents that might develop at a de-energized worksite during maintenance of ac overhead and underground, transmission and distribution lines, cables, and equipment. Other forms of worker protection include isolation and insulation. These methods are described in other documents and guides and are not discussed here.
Standards approved by the IEEE SA Standards Board that are within the 10-year lifecycle.
1048a-2021
IEEE Guide for Protective Grounding of Power Lines - Amendment 1
Guidelines are provided for Temporary Protective Grounding (TPG) of electric power lines to assist in protection of workers from voltages and currents that might develop at a de-energized worksite during maintenance of ac overhead and underground, transmission and distribution lines, cables, and equipment. Other forms of worker protection include isolation and insulation. These methods are described in other documents and guides and are not discussed here.
These standards have been replaced with a revised version of the standard, or by a compilation of the original active standard and all its existing amendments, corrigenda, and errata.
1048-2003
IEEE Guide for Protective Grounding of Power Lines
Guidelines for protective grounding methods for individuals engaged in de-energized overhead transmission and distribution line maintenance are provided. This guide also provides information on the sizing and maintenance of protective ground sets. It is a compilation of information on protective grounding practice employed by North American power utilities.
These standards have been removed from active status through a ballot where the standard is made inactive as a consensus decision of a balloting group.