Information is provided to users and manufacturers of surge-protective devices(SPDs) about the interactions that may occur between SPDs and power system disturbances. This guide applies to SPDs manufactured to be connected to 50 or 60 Hz ac power circuits rated at 100-1000 V rms. The effects and side effects of the presence and operation of SPDs on the quality of power available to the connected loads are described. The interaction between multiple SPDs on the same circuit is also described.
- Standard Committee
- PE/SPDLV - Surge Protective Devices/Low Voltage
- Status
- Superseded Standard
- Superseded by
- C62.48-2005
- Board Approval
- 1995-06-14
- History
-
- Published:
- 1995-12-15
- Reaffirmed:
- 2000-06-21
Working Group Details
- Society
- IEEE Power and Energy Society
- Standard Committee
- PE/SPDLV - Surge Protective Devices/Low Voltage
- Working Group
-
LV3.6.4 - 3.6.4 Surge Characterization on LV Circuits WG
- IEEE Program Manager
- Christian Orlando
Contact Christian Orlando - Working Group Chair
- Douglas Dorr
Other Activities From This Working Group
Current projects that have been authorized by the IEEE SA Standards Board to develop a standard.
PC62.41.2
Recommended Practice on Characterization of Surges in Low-Voltage (1000 V and less) AC Power Circuits
The scope of this recommended practice is to characterize the surge environment at locations on ac power circuits described in IEEE Std C62.41.1 by means of standardized waveforms and other stress parameters. The surges considered in this recommended practice do not exceed one half-cycle of the normal mains waveform (fundamental frequency) in duration. They can be periodic or random events and can appear in any combination of line, neutral, or grounding conductors. They include surges with amplitudes, durations, or rates of change sufficient to cause equipment damage or operational upset. While surge protective devices (SPDs) acting primarily on the amplitude of the voltage or current are often applied to divert the damaging surges, the upsetting surges might require other remedies.
Standards approved by the IEEE SA Standards Board that are within the 10-year lifecycle.
No Active Standards
These standards have been replaced with a revised version of the standard, or by a compilation of the original active standard and all its existing amendments, corrigenda, and errata.
No Superseded Standards
These standards have been removed from active status through a ballot where the standard is made inactive as a consensus decision of a balloting group.
No Inactive-Withdrawn Standards
These standards are removed from active status through an administrative process for standards that have not undergone a revision process within 10 years.
No Inactive-Reserved Standards