Inactive-Withdrawn Standard

IEEE/ANSI C57.12.24-1994

American National Standard for Transformers-- Underground-Type Three-Phase Distribution Transformers, 2500 kVA and Smaller, High Voltage, 34 500 GrdY/19 920 Volts and Below, Low Voltage, 480 Volts and Below - Requirements

1.1 This standard is intended to set forth characteristics relating to performance, limited electrical and mechanical interchangeability, and safety of the equipment described, and to assist in the proper selection of such equipment. NOTE – Refer to the latest Federal Regulations concerning polychlorinated biphenyls (PCB) contamination in transformers. 1.2 This standard describes certain electrical and mechanical characteristics and takes into consideration certain safety features of three-phase, 60-Hz, liquid-immersed, self-cooled, underground-type distribution transformers rated 2500 kVA and smaller with high voltages of 34 500GrdY/19 920 volts and below and with low voltages of 480 volts and below. These transformers are generally used for step-down purposes from an underground primary cable supply and are suitable for occasional submerged operation. 1.3 This standard does not cover the electrical and mechanical requirements of any accessory devices that may be supplied with the transformer.

Standard Committee
PE/TR - Transformers
Status
Inactive-Withdrawn Standard
Superseded by
C57.12.24-2000
Board Approval
1994-03-17
History
Withdrawn:
2001-01-15
Published:
1994-05-24

Working Group Details

Society
IEEE Power and Energy Society
Standard Committee
PE/TR - Transformers

Other Activities From This Working Group

Current projects that have been authorized by the IEEE SA Standards Board to develop a standard.


No Active Projects

Standards approved by the IEEE SA Standards Board that are within the 10-year lifecycle.


C57.12.24-2023
IEEE Standard for Submersible, Three-Phase Transformers, 3750 kVA and Smaller: High Voltage, 34 500 GrdY/19 920 V and Below; Low Voltage, 600 V and Below

Certain electrical, dimensional, and mechanical characteristics are covered in this standard. Certain safety features of three-phase, 60-Hz, liquid-immersed, self-cooled, submersible transformers with separable insulated high-voltage connectors are also taken into consideration These transformers are rated 3750 kVA and smaller with high voltages of 34 500 GrdY/19 920 V and below and with low voltages of 600 V and below.

Learn More About C57.12.24-2023

These standards have been replaced with a revised version of the standard, or by a compilation of the original active standard and all its existing amendments, corrigenda, and errata.


C57.12.24-2009
IEEE Standard for Submersible, Three-Phase Transformers, 3750 kVA and Smaller: High Voltage, 34 500 GrdY/19 920 Volts and Below; Low Voltage, 600 Volts and Below

This standard is intended for use as a basis for establishing the performance, electrical and mechanical interchangeability, and safety of the equipment covered, and to assist in the proper selection of such equipment.

Learn More About C57.12.24-2009

C57.12.24-2016
IEEE Standard for Submersible, Three-Phase Transformers, 3750 kVA and Smaller: High Voltage, 34 500 GrdY/19 920 Volts and Below; Low Voltage, 600 Volts and Below

Certain electrical, dimensional, and mechanical characteristics are covered in this standard. It also takes into consideration certain safety features of three-phase, 60 Hz, liquid-immersed, self-cooled, submersible transformers with separable insulated high-voltage connectors. These transformers are rated 3750 kVA and smaller with high voltages of 34 500 GrdY/19 920 V and below and with low voltages of 600 V and below.

Learn More About C57.12.24-2016

These standards have been removed from active status through a ballot where the standard is made inactive as a consensus decision of a balloting group.


C57.12.24-2000
American National Standard for Transformers-- Underground-Type Three-Phase Distribution Transformers 2500 kVA and Smaller; High Voltage: 34,500 GrdY/29 920 Volts and Below; Low Voltage: 480 Volts and Below--Requirements

This standard describes certain electrical and mechanical characteristics and takes into consideration certain safety features of three phase, 60-Hz, liquid-immersed, self-cooled, underground type distribution transformers rated 2500 kVA and smaller with high voltages of 34 500GrdY/19 920 volts and below and with low voltages of 480 volts and below. These transformers are generally used for step down purposes from an underground primary cable supply and are suitable for occasional submerged operation.

Learn More About C57.12.24-2000

These standards are removed from active status through an administrative process for standards that have not undergone a revision process within 10 years.


No Inactive-Reserved Standards
Subscribe to our Newsletter

Sign up for our monthly newsletter to learn about new developments, including resources, insights and more.