Superseded Standard

IEEE C37.015-2009

IEEE Guide for the Application of Shunt Reactor Switching

This application guide applies to ac high-voltage circuit breakers rated for shunt reactor switching. The guide covers the specific cases of switching directly grounded shunt reactors, ungrounded shunt reactors and shunt reactors grounded through a neutral reactor. Directly grounded reactors are common on systems having a voltage of 60 kV and above, while ungrounded reactors are commonly applied on systems having a voltage below 60 kV. Schemes where the reactor is grounded through a neutral reactor are usually only applied on systems having a voltage of 60 kV and above. Whereas this application guide is directed towards circuit breakers, it is recognized and accepted that other switching devices such as high voltage load break switches and circuit switchers are capable of shunt reactor switching and this guide may be applied as appropriate.

Sponsor Committee
PE/SWG - Switchgear
Learn More About PE/SWG - Switchgear
Status
Superseded Standard
PAR Approval
2008-09-26
Superseded by
C37.015-2017
Superseding
C37.015-1993
Board Approval
2009-12-09
History
ANSI Approved:
2010-07-01
Published:
2010-02-12

Working Group Details

Society
IEEE Power and Energy Society
Learn More About IEEE Power and Energy Society
Sponsor Committee
PE/SWG - Switchgear
Learn More About PE/SWG - Switchgear
Working Group
HVCB/C37.015 - C37.015 - Guide for the Application of Shunt Reactor Switching
IEEE Program Manager
Jennifer Santulli
Contact Jennifer Santulli
Working Group Chair
Michael Crawford

Other Activities From This Working Group

Current projects that have been authorized by the IEEE SA Standards Board to develop a standard.


PC37.015
Guide for the Application of Shunt Reactor Switching

This application guide applies to ac high-voltage (> 1000 V) circuit breakers rated for shunt reactor switching. This application guide provides the theoretical background of shunt reactor switching and how information obtained from test results and system studies should be used to predict overvoltages in the field and gives suggestions how to mitigate these overvoltages.

Learn More About PC37.015

Standards approved by the IEEE SA Standards Board that are within the 10-year lifecycle.


C37.015-2017
IEEE Guide for the Application of Shunt Reactor Switching

Guidance for the application of ac high-voltage circuit breakers for shunt reactor switching is provided. Overvoltage generation for the three cases of shunt reactors being directly grounded, ungrounded, or grounded through a neutral reactor is addressed in terms of derivation and limitation methods. Circuit breaker specification for the purpose and the use of laboratory test results to predict field performance is also covered by this guide.

Learn More About C37.015-2017

These standards have been replaced with a revised version of the standard, or by a compilation of the original active standard and all its existing amendments, corrigenda, and errata.


C37.015-1993
IEEE Application Guide for Shunt Reactor Switching

Guidance for the application of ac high-voltage circuit breakers for shunt reactor switching is provided. Overvoltage generation for the three cases of directly grounded, ungrounded, and neutral reactor grounded shunt reactors is addressed in terms of derivation and limitation methods. Circuit breaker specification for the purpose and the use of laboratory test results to predict field performance is also covered by this guide.

Learn More About C37.015-1993

These standards have been removed from active status through a ballot where the standard is made inactive as a consensus decision of a balloting group.


No Inactive-Withdrawn Standards

These standards are removed from active status through an administrative process for standards that have not undergone a revision process within 10 years.


No Inactive-Reserved Standards
Subscribe to our Newsletter

Sign up for our monthly newsletter to learn about new developments, including resources, insights and more.