Outdoor ac substations, either conventional or gas-insulated, are covered in this guide. Distribution, transmission, and generating plant substations are also included. With proper caution,the methods described herein are also applicable to indoor portions of such substations, or to sub-stations that are wholly indoors. No attempt is made to cover the grounding problems peculiar to dc substations. A quantitative analysis of the effects of lightning surges is also beyond the scope of this guide.
- Sponsor Committee
- PE/SUB - Substations Committee
Learn More About PE/SUB - Substations Committee - Status
- Superseded Standard
- Superseded by
- 80-2013
- Superseding
- 80-1986
- Board Approval
- 2000-01-30
- History
-
- ANSI Approved:
- 2000-07-18
- ANSI Withdrawn Date:
- 2011-09-09
- Published:
- 2000-08-04
Additional Resources
- Erratas
- 80-2000_errata.pdf
- Interpretation
- 80-2000_interp.pdf
Working Group Details
- Society
- IEEE Power and Energy Society
Learn More About IEEE Power and Energy Society - Sponsor Committee
- PE/SUB - Substations Committee
Learn More About PE/SUB - Substations Committee - Working Group
-
WGG4 - WGG4 - Temporary Protective Grounding in Substations
- IEEE Program Manager
- Patricia Roder
Contact Patricia Roder - Working Group Chair
- Jesse Rorabaugh
Other Activities From This Working Group
Current projects that have been authorized by the IEEE SA Standards Board to develop a standard.
P1246
IEEE Draft Guide for Temporary Protective Grounding Systems Used in Substations
The design, performance, use, testing, and installation of temporary protective grounding systems, including the connection points, as used in permanent and mobile substations, are covered in this guide.
P1268
Guide for Safety in Installation and Operation of Mobile Substation Equipment
This guide contains information on general topics and items pertaining to safety when installing and operating mobile substation equipment. The guide recognizes that mobile substation equipment varies widely. It is beyond the scope of this guide to provide specific step-by-step instructions for individual units.
Standards approved by the IEEE SA Standards Board that are within the 10-year lifecycle.
1246-2020
IEEE Guide for Temporary Protective Grounding Systems Used in Substations
The design, performance, use, testing, and installation of temporary protective grounding systems, including the connection points, as used in permanent and mobile substations, are covered in this guide.
1268-2016
IEEE Guide for Safety in the Installation of Mobile Substation Equipment
Information pertaining to the installation of mobile substation equipment up to 245 kV is provided in this guide.
These standards have been replaced with a revised version of the standard, or by a compilation of the original active standard and all its existing amendments, corrigenda, and errata.
1246-2002
IEEE Guide for Temporary Protective Grounding Systems Used in Substations
The design, performance, use, testing, and installation of temporary protectivegrounding systems, including the connection points, as used in permanent and mobile substations,are covered in this guide.
1246-2011
IEEE Guide for Temporary Protective Grounding Systems Used in Substations
The design, performance, use, testing, and installation of temporary protective grounding systems, including the connection points, as used in permanent and mobile substations, are covered in this guide.
1268-2005
IEEE Guide for Safety in the Installation of Mobile Substation Equipment
Information pertaining to the installation of mobile substation equipment up to 245 kV is provided in this guide.
These standards have been removed from active status through a ballot where the standard is made inactive as a consensus decision of a balloting group.
No Inactive-Withdrawn Standards
These standards are removed from active status through an administrative process for standards that have not undergone a revision process within 10 years.
No Inactive-Reserved Standards