Active PAR

P400.2

Guide for Field Testing of Shielded Power Cable Systems Using Very Low Frequency (VLF) (less than 1 Hz)

This guide describes VLF withstand and other diagnostic tests and the measurements that are performed in the field on shielded medium and high-voltage cables rated 5 kV and above with extruded and laminated insulation. VLF test methods utilize ac signals at frequencies less than 1 Hz. The most commonly used, commercially available, VLF test frequency is 0.1 Hz. Whenever possible the guide addresses testing of complete cable systems. Tables are included of the recommended test voltage levels for installation, acceptance, and maintenance tests.

Sponsor Committee
PE/IC - Insulated Conductors
Learn More
Status
Active PAR
PAR Approval
2022-09-21
Superseding
400.2-2013

Working Group Details

Society
IEEE Power and Energy Society
Learn More
Sponsor Committee
PE/IC - Insulated Conductors
Learn More
Working Group
F03W/P400.2_WG - Working group for the Guide for Field Testing of Shielded Power Cable Systems Using Very Low Frequency (VLF)
Learn More
IEEE Program Manager
Ron Hotchkiss
Contact
Working Group Chair
Robert Hampton

Other Activities From This Working Group

Current projects that have been authorized by the IEEE SA Standards Board to develop a standard.


No Active Projects

Standards approved by the IEEE SA Standards Board that are within the 10-year lifecycle.


400.2-2013

IEEE Guide for Field Testing of Shielded Power Cable Systems Using Very Low Frequency (VLF)(less than 1 Hz)

Very low frequency (VLF) withstand and other diagnostic tests and measurements that are performed using VLF energization in the field on shielded power cable systems are described in this guide. Whenever possible, cable systems are treated in a similar manner to individual cables. Tables are included as an aid to identifying the effectiveness of the VLF ac voltage test for various cable system insulation problems.

Learn More

These standards have been replaced with a revised version of the standard, or by a compilation of the original active standard and all its existing amendments, corrigenda, and errata.


No Superseded Standards

These standards have been removed from active status through a ballot where the standard is made inactive as a consensus decision of a balloting group.


No Inactive-Withdrawn Standards

These standards are removed from active status through an administrative process for standards that have not undergone a revision process within 10 years.


No Inactive-Reserved Standards