General recommendations for the in-service care, maintenance, and testing of the conductive clothing worn by workers to perform work in high voltage fields.
- Standard Committee
- PE/T&D - Transmission and Distribution
- Status
- Superseded Standard
- PAR Approval
- 1999-03-18
- Superseded by
- 1067-2012
- Superseding
- 1067-1996
- Board Approval
- 2005-02-14
- History
-
- ANSI Approved:
- 2005-05-06
- Published:
- 2005-08-31
Working Group Details
- Society
- IEEE Power and Energy Society
- Standard Committee
- PE/T&D - Transmission and Distribution
- Working Group
-
ESMOL-1067_WG - IEEE Guide for In-Service Use, Care, Maintenance, and Testing of Conductive Clothing for Use on Voltages up to 765 kV ac and 750 kV dc
- IEEE Program Manager
- Michael Kipness
Contact Michael Kipness - Working Group Chair
- Balint Nemeth
Other Activities From This Working Group
Current projects that have been authorized by the IEEE SA Standards Board to develop a standard.
P1067
Guide for In-Service Use, Care, Maintenance, and Testing of Conductive Clothing Used for Live Work and Power Frequency AC Induction Protection
This is a guide for the in-service visual inspection, use, care, maintenance, and electrical testing of conductive clothing, including suits, gloves, socks, boots, bondings and face-screen for use during: -- Live work on voltages 765 kV AC (Type 1) and below -- Live work on voltage 750 kV DC (Type 1) and below -- Power frequency AC induction protection (Type 2) This compilation of many accepted practices is presented specifically in the form of a guide to be used by those utilities that are seeking guidance in establishing methods and procedures for the use, care, maintenance, and testing of conductive clothing.
Standards approved by the IEEE SA Standards Board that are within the 10-year lifecycle.
No Active Standards
These standards have been replaced with a revised version of the standard, or by a compilation of the original active standard and all its existing amendments, corrigenda, and errata.
No Superseded Standards
These standards have been removed from active status through a ballot where the standard is made inactive as a consensus decision of a balloting group.
No Inactive-Withdrawn Standards
These standards are removed from active status through an administrative process for standards that have not undergone a revision process within 10 years.
1067-2012
IEEE Guide for In-Service Use, Care, Maintenance, and Testing of Conductive Clothing for Use on Voltages up to 765 kV AC and +/-750 kV DC
General recommendations for the in-service care, maintenance, and testing of the conductive clothing worn by workers to perform work in high-voltage fields are presented.