Active PAR

P1067

Guide for In-Service Use, Care, Maintenance, and Testing of Conductive Clothing Used for Live Work and Power Frequency AC Induction Protection

This is a guide for the in-service visual inspection, use, care, maintenance, and electrical testing of conductive clothing, including suits, gloves, socks, boots, bondings and face-screen for use during: -- Live work on voltages 765 kV AC (Type 1) and below -- Live work on voltage 750 kV DC (Type 1) and below -- Power frequency AC induction protection (Type 2) This compilation of many accepted practices is presented specifically in the form of a guide to be used by those utilities that are seeking guidance in establishing methods and procedures for the use, care, maintenance, and testing of conductive clothing.

Standard Committee
PE/T&D - Transmission and Distribution
Status
Active PAR
PAR Approval
2024-09-26
Superseding
1067-2012

Working Group Details

Society
IEEE Power and Energy Society
Standard Committee
PE/T&D - Transmission and Distribution
Working Group
ESMOL-1067_WG - IEEE Guide for In-Service Use, Care, Maintenance, and Testing of Conductive Clothing for Use on Voltages up to 765 kV ac and 750 kV dc
IEEE Program Manager
Michael Kipness
Contact Michael Kipness
Working Group Chair
Balint Nemeth

Other Activities From This Working Group

Current projects that have been authorized by the IEEE SA Standards Board to develop a standard.


No Active Projects

Standards approved by the IEEE SA Standards Board that are within the 10-year lifecycle.


No Active Standards

These standards have been replaced with a revised version of the standard, or by a compilation of the original active standard and all its existing amendments, corrigenda, and errata.


1067-2005
IEEE Guide for In-Service Use, Care, Maintenance and Testing of Conductive Clothing for Use on Voltages up to 765 kV AC and 750 kV DC

General recommendations for the in-service care, maintenance, and testing of the conductive clothing worn by workers to perform work in high voltage fields.

Learn More About 1067-2005

These standards have been removed from active status through a ballot where the standard is made inactive as a consensus decision of a balloting group.


No Inactive-Withdrawn Standards

These standards are removed from active status through an administrative process for standards that have not undergone a revision process within 10 years.


1067-2012
IEEE Guide for In-Service Use, Care, Maintenance, and Testing of Conductive Clothing for Use on Voltages up to 765 kV AC and +/-750 kV DC

General recommendations for the in-service care, maintenance, and testing of the conductive clothing worn by workers to perform work in high-voltage fields are presented.

Learn More About 1067-2012

Subscribe to our Newsletter

Sign up for our monthly newsletter to learn about new developments, including resources, insights and more.