Tag: Power and Energy

IEEE Standard Design Tests for High-Voltage Fuses, Distribution Enclosed Single-Pole Air Switches, Fuse Disconnecting Switches and Accessories

Required procedures for performing design tests for high-voltage distribution-class and power-class fuses, as well as for fuse disconnecting switches and enclosed single-pole air switches are specified. These design tests, as…

IEEE Standard Design Tests for High-Voltage Fuses, Distribution Enclosed Single-Pole Air Switches, Fuse Disconnecting Switches, and Accessories

Superseded. Tests for high-voltage fuses (above 600 V), distribution enclosed single-pole air switches, fuse disconnecting switches, and accessories (for AC distribution systems) are covered. These include enclosed, open, and open-link…

IEEE Standard Design Tests For High-Voltage Fuses, Distribution Enclosed Single-Pole Air Switches, Fuse Disconnecting Switches, and Accessories

Required procedures for performing design tests for high-voltage distribution-class and power-class fuses, as well as for fuse disconnecting switches and enclosed single-pole air switches are specified. These design tests, as…

IEEE Test Standard for Expulsion Fuses in Enclosures (Supplement to C37.41-1988)

Supplement to C37.41-1988, IEEE test standard for expulsion fuses in enclosures, procedures are given for performance testing of liquid-submerged and in-air expulsion fuses in enclosures

X/R Values for Interrupting Tests on Slant Rated Cutouts

IEEE Standard Design Tests for External Fuses for Shunt Capacitors – Supplement to IEEE Std C37.41-1994

The design testing required for high-voltage external capacitor fuses (above 1000 V) used for the protection of shunt capacitor banks is covered in this supplement.

Mechanical Design Tests for Distribution Cutouts

IEEE Guide for Application, Operation, and Maintenance of High-Voltage Fuses, Distribution Enclosed Single-Pole Air Switches, Fuse Disconnecting Switches, and Accessories

Superseded. Information on the application, operation, and maintenance of high-voltage fuses (above 1000 V), distribution enclosed single-pole air switches, fuse disconnecting switches, and accessories for use on AC distribution systems…

IEEE Guide for the Application, Operation, and Maintenance of High-Voltage Fuses, Distribution Enclosed Single-Pole Air Switches, Fuse Disconnecting Switches, and Accessories

Information on the application, operation and maintenance of high-voltage fuses (above 1000 V), distribution enclosed single-pole air switches, fuse disconnecting switches, and accessories for use on ac distribution systems is…