Standard Details
Methods for performing tests specified in IEEE Std C57.12.00(TM) and other standards applicable to liquid-immersed distribution, power, and regulating transformers are described. Instrument transformers, step-voltage and induction voltage regulators, arc furnace transformers, rectifier transformers, specialty transformers, grounding transformers, and mine transformers are excluded. This standard covers resistance measurements, polarity and phase-relation tests, ratio tests, no-load loss and excitation current measurements, impedance and load loss measurements, dielectric tests, temperature tests, short-circuit tests, audible sound level measurements, and calculated data.
Sponsor Committee | |
Status |
Superseded
|
Superseded by | |
Board Approval |
2010-06-17
|
History |
Published Date:2010-10-15
|
Additional Resources Details
PAR | |
Historical Base Standard |
Working Group Details
Working Group |
Stds WG - Cont. Revision of C5 - Standards Working Group on the Continuous Revision of C57.12.90
|
Working Group Chair |
Stephen Antosz
|
Sponsor Committee | |
Society | |
IEEE Program Manager | |
Active Projects |
PC57.12.90 - Standard Test Code for Liquid-Immersed Distribution, Power, and Regulating Transformers
This standard describes methods for performing tests specified in IEEE Std C57.12.00(TM) and other standards applicable to liquid-immersed distribution, power, and regulating transformers. It is intended for use as a basis for performance and proper testing of such transformers. This standard applies to all liquid-immersed transformers, except instrument transformers, step-voltage and induction voltage regulators, arc furnace transformers, rectifier transformers, specialty transformers, grounding transformers, and mine transformers. Transformer requirements and specific test criteria are not a part of this standard, but they are contained in appropriate standards, such as IEEE Std C57.12.00, IEEE Std C57.12.10(TM), IEEE Std C57.12.20(TM), and IEEE Std C57.12.40(TM), or in user specifications.
|
Existing Standards |
Methods for performing tests specified in IEEE Std C57.12.00TM-2006 and other standards applicable to liquid-immersed distribution, power, and regulating transformers are described. Instrument transformers, step-voltage and induction voltage regulators, arc furnace transformers, rectifier transformers, specialty transformers, grounding transformers, and mine transformers are excluded. This standard covers resistance measurements, polarity and phaserelation tests, ratio tests, no-load-loss and excitation current measurements, impedance and load loss measurements, dielectric tests, temperature tests, short-circuit tests, audible sound level measurements, calculated data, and certified test data.
|
Methods for performing tests specified in IEEE Std C57.12.00(TM) and other standards applicable to liquid-immersed distribution, power, and regulating transformers are described. Instrument transformers, step-voltage and induction voltage regulators, arc furnace transformers, rectifier transformers, specialty transformers, grounding transformers, and mine transformers are excluded. Resistance measurements, polarity and phase-relation tests, ratio tests, no-load loss and excitation current measurements, impedance and load loss measurements, dielectric tests, temperature tests, short-circuit tests, audible sound level measurements, and calculated data are
covered in this standard.
|
|
The definition of constant k in Equation 2 (in 8.3) and line terminal rated voltage in the last paragraph of 10.8.2 are corrected in this corrigendum.
|