IEEE C57.12.01-2020

IEEE Standard for General Requirements for Dry-Type Distribution and Power Transformers

Electrical, mechanical, and safety requirements of ventilated, non-ventilated, and sealed dry-type distribution and power transformers or autotransformers (single and polyphase, with a voltage of 601 V or higher in the highest voltage winding) are described in this standard.

Sponsor Committee
PE/TR - Transformers
Learn More About PE/TR - Transformers
Status
Active Standard
PAR Approval
2016-05-12
Superseding
C57.12.01-2015
Board Approval
2020-09-24
History
Published:
2020-11-24

Working Group Details

Society
IEEE Power and Energy Society
Learn More About IEEE Power and Energy Society
Sponsor Committee
PE/TR - Transformers
Learn More About PE/TR - Transformers
Working Group
DryType-WGC57.12.01 - Dry Type Transformers - General Req. Working Group
IEEE Program Manager
Patrycja Jarosz
Contact Patrycja Jarosz
Working Group Chair
Robert Ballard

Other Activities From This Working Group

Current projects that have been authorized by the IEEE SA Standards Board to develop a standard.


PC57.12.01

Standard for General Requirements for Dry-Type Distribution and Power Transformers

This standard defines the electrical and mechanical requirements of single and polyphase ventilated, nonventilated, and sealed dry-type distribution and power transformers or autotransformers, with a voltage of 601V or higher in the highest voltage winding. This standard applies to all dry-type transformers, including those with solid-cast and/or resin encapsulated windings except as follows:na) Instrument transformersnb) Step and induction-voltage regulatorsnc) Arc-furnace transformersnd) Rectifier transformersne) Specialty and general-purpose transformersnf) Mine transformersng) Testing transformersnh) Welding transformersni) Drive transformersnj) Inverter transformers

Learn More About PC57.12.01

Standards approved by the IEEE SA Standards Board that are within the 10-year lifecycle.


No Active Standards

These standards have been replaced with a revised version of the standard, or by a compilation of the original active standard and all its existing amendments, corrigenda, and errata.


C57.12.01-1979

American National Standard General Requirements for Dry-Type Distribution and Power Transformers

Electrical, mechanical, and safety requirements of ventilated, nonventilated, and sealed dry-type distribution and power transformers or autotransformers, single and polyphase, with a voltage of 601 V or higher in the highest voltage winding, are described. Information that can be used as a basis for the establishment of performance, interchangeability, and safety requirements of equipment described, and for assistance in the proper selection of such equipment, is given.

Learn More About C57.12.01-1979

C57.12.01-1998

IEEE Standard General Requirements for Dry-Type Distribution and Power Transformers Including Those with Solid Cast and/or Resin Encapsulated Windings

Superseded by IEEE Std C57.12.01-2005 Electrical, mechanical, and safety requirements of ventilated, nonventilated, and sealed dry-type distribution and power transformers or autotransformers, single and polyphase, with a voltage of 601 V or higher in the highest voltage winding, are described. Information that can be used as a basis for the establishment of performance, interchangeability, and safety requirements of equipment described, and for assistance in the proper selection of such equipment, is given.

Learn More About C57.12.01-1998

C57.12.01-2005

IEEE Standard General Requirements for Dry-Type Distribution and Power Transformers Including Those with Solid Cast and/or Resin Encapsulated Windings

Electrical, mechanical, and safety requirements of ventilated, non-ventilated, and sealed dry-type distribution and power transformers or auto transformers (single and polyphase, with a voltage of 601 V or higher in the highest voltage winding) are described.

Learn More About C57.12.01-2005

C57.12.01-2015

IEEE Standard for General Requirements for Dry-Type Distribution and Power Transformers

Electrical and mechanical requirements of ventilated, non-ventilated, and sealed dry-type distribution and power transformers or autotransformers (single and polyphase, with a voltage of 601 V or higher in the highest voltage winding) are described.

Learn More About C57.12.01-2015

These standards have been removed from active status through a ballot where the standard is made inactive as a consensus decision of a balloting group.


No Inactive-Withdrawn Standards

These standards are removed from active status through an administrative process for standards that have not undergone a revision process within 10 years.


No Inactive-Reserved Standards
Subscribe to our Newsletter

Sign up for our monthly newsletter to learn about new developments, including resources, insights and more.