Superseded Standard

IEEE C37.112-1996

IEEE Standard Inverse-Time Characteristic Equations for Overcurrent Relays

The inverse-time characteristics of overcurrent relays are defined in this standard. Operating equations and allowances are provided in the standard. The standard defines an integral equation for microprocessor relays that ensures coordination not only in the case of constant current input but for any current condition of varying magnitude. Electromechanical inverse-time overcurrent relay reset characteristics are defined in the event that designers of microprocessor based relays and computer relays want to match the reset characteristics of the electromechanical relays.

Sponsor Committee
PE/PSRCC - Power System Relaying and Control
Learn More About PE/PSRCC - Power System Relaying and Control
Status
Superseded Standard
Superseded by
C37.112-2018
Board Approval
1996-09-19
History
ANSI Approved:
1997-02-27
Published:
1996-11-30
Reaffirmed:
2007-03-08

Working Group Details

Society
IEEE Power and Energy Society
Learn More About IEEE Power and Energy Society
Sponsor Committee
PE/PSRCC - Power System Relaying and Control
Learn More About PE/PSRCC - Power System Relaying and Control
Working Group
C37.112_WG - Inverse-Time Characteristic Equations for Overcurrent Relays
IEEE Program Manager
Malia Zaman
Contact Malia Zaman
Working Group Chair
Randall Crellin

Other Activities From This Working Group

Current projects that have been authorized by the IEEE SA Standards Board to develop a standard.


No Active Projects

Standards approved by the IEEE SA Standards Board that are within the 10-year lifecycle.


C37.112-2018

IEEE Standard for Inverse-Time Characteristics Equations for Overcurrent Relays

The inverse-time characteristics of overcurrent relays are defined in this standard. Operating equations and allowances are provided in the standard. The standard defines an integral equation for microprocessor relays that ensures coordination not only in the case of constant current input but for any current condition of varying magnitude. Electromechanical inverse-time overcurrent relay reset characteristics are defined in the event that designers of microprocessor based relays and computer relays want to match the reset characteristics of the electromechanical relays.

Learn More About C37.112-2018

These standards have been replaced with a revised version of the standard, or by a compilation of the original active standard and all its existing amendments, corrigenda, and errata.


No Superseded Standards

These standards have been removed from active status through a ballot where the standard is made inactive as a consensus decision of a balloting group.


No Inactive-Withdrawn Standards

These standards are removed from active status through an administrative process for standards that have not undergone a revision process within 10 years.


No Inactive-Reserved Standards
Subscribe to our Newsletter

Sign up for our monthly newsletter to learn about new developments, including resources, insights and more.