IEEE C37.011-2011

IEEE Guide for the Application of Transient Recovery Voltage for AC High-Voltage Circuit Breakers

Procedures and calculations necessary to apply the standard transient recovery voltage (TRV) ratings for ac high-voltage circuit breakers rated above 1000 V are covered in this application guide. The breaking capability limits of these circuit breakers are determined to a great degree by the TRV. The TRV ratings are compared with typical system TRV duties. Examples of TRV calculation are given with suggested options if the TRV duty exceeds the TRV ratings of the circuit breaker.

Sponsor Committee
PE/SWG - Switchgear
Learn More About PE/SWG - Switchgear
Status
Superseded Standard
PAR Approval
2009-12-09
Superseded by
C37.011-2019
Superseding
C37.011-2005
Board Approval
2011-10-31
History
ANSI Approved:
2013-01-15
Published:
2011-11-28

Working Group Details

Society
IEEE Power and Energy Society
Learn More About IEEE Power and Energy Society
Sponsor Committee
PE/SWG - Switchgear
Learn More About PE/SWG - Switchgear
Working Group
HVCB/C37.011 - C37.011 - Guide for the Application of Transient Recovery Voltage for AC High-Voltage Circuit Breakers with Rated Maximum Voltage above 1000 V
IEEE Program Manager
Jennifer Santulli
Contact Jennifer Santulli
Working Group Chair
Denis Dufournet

Other Activities From This Working Group

Current projects that have been authorized by the IEEE SA Standards Board to develop a standard.


No Active Projects

Standards approved by the IEEE SA Standards Board that are within the 10-year lifecycle.


C37.011-2019

IEEE Guide for the Application of Transient Recovery Voltage for AC High-Voltage Circuit Breakers with Rated Maximum Voltage above 1000 V

The procedures and calculations necessary to apply the standard transient recovery voltage (TRV) ratings for ac high-voltage circuit breakers rated above 1000 V are covered in this guide. The breaking capability limits of these circuit breakers are determined to a great degree by the TRV. The TRV ratings are compared with typical system TRV duties. Examples of TRV calculation are given with suggested options if the TRV duty exceeds the TRV ratings of the circuit breaker.

Learn More About C37.011-2019

These standards have been replaced with a revised version of the standard, or by a compilation of the original active standard and all its existing amendments, corrigenda, and errata.


C37.011-2005

IEEE Application Guide for Transient Recovery Voltage for AC High-Voltage Circuit Breakers

Revision of IEEE Std C37.011-1994 Procedures and calculations necessary to apply the standard transient recovery voltage (TRV) ratings for ac high-voltage circuit breakers rated above 1000 V and on a symmetrical current basis are covered. The capability limits of these circuit breakers are determined to a great degree by the TRV. TRV ratings are compared with typical system TRV duties.

Learn More About C37.011-2005

These standards have been removed from active status through a ballot where the standard is made inactive as a consensus decision of a balloting group.


No Inactive-Withdrawn Standards

These standards are removed from active status through an administrative process for standards that have not undergone a revision process within 10 years.


No Inactive-Reserved Standards
Subscribe to our Newsletter

Sign up for our monthly newsletter to learn about new developments, including resources, insights and more.