Revision of IEEE Std C37.011-1994 Procedures and calculations necessary to apply the standard transient recovery voltage (TRV) ratings for ac high-voltage circuit breakers rated above 1000 V and on a symmetrical current basis are covered. The capability limits of these circuit breakers are determined to a great degree by the TRV. TRV ratings are compared with typical system TRV duties.
- Standard Committee
- PE/SWG - Switchgear
- Status
- Superseded Standard
- PAR Approval
- 2001-12-06
- Superseded by
- C37.011-2011
- Superseding
- C37.011-1994
- Board Approval
- 2005-09-22
- History
-
- ANSI Approved:
- 2005-12-29
- Published:
- 2006-02-10
Working Group Details
- Society
- IEEE Power and Energy Society
- Standard Committee
- PE/SWG - Switchgear
- Working Group
-
HVCB/C37.011 - C37.011 - Guide for the Application of Transient Recovery Voltage for AC High-Voltage Circuit Breakers with Rated Maximum Voltage above 1000 V
- IEEE Program Manager
- Jennifer Santulli
Contact Jennifer Santulli - Working Group Chair
- Denis Dufournet
Other Activities From This Working Group
Current projects that have been authorized by the IEEE SA Standards Board to develop a standard.
No Active Projects
Standards approved by the IEEE SA Standards Board that are within the 10-year lifecycle.
C37.011-2019
IEEE Guide for the Application of Transient Recovery Voltage for AC High-Voltage Circuit Breakers with Rated Maximum Voltage above 1000 V
The procedures and calculations necessary to apply the standard transient recovery voltage (TRV) ratings for ac high-voltage circuit breakers rated above 1000 V are covered in this guide. The breaking capability limits of these circuit breakers are determined to a great degree by the TRV. The TRV ratings are compared with typical system TRV duties. Examples of TRV calculation are given with suggested options if the TRV duty exceeds the TRV ratings of the circuit breaker.
These standards have been replaced with a revised version of the standard, or by a compilation of the original active standard and all its existing amendments, corrigenda, and errata.
C37.011-2011
IEEE Guide for the Application of Transient Recovery Voltage for AC High-Voltage Circuit Breakers
Procedures and calculations necessary to apply the standard transient recovery voltage (TRV) ratings for ac high-voltage circuit breakers rated above 1000 V are covered in this application guide. The breaking capability limits of these circuit breakers are determined to a great degree by the TRV. The TRV ratings are compared with typical system TRV duties. Examples of TRV calculation are given with suggested options if the TRV duty exceeds the TRV ratings of the circuit breaker.
These standards have been removed from active status through a ballot where the standard is made inactive as a consensus decision of a balloting group.
No Inactive-Withdrawn Standards
These standards are removed from active status through an administrative process for standards that have not undergone a revision process within 10 years.
No Inactive-Reserved Standards