Active Standard

IEEE C62.62-2018

IEEE Standard Test Specifications for Surge-Protective Devices (SPDs) for Use on the Load Side of the Service Equipment in Low-Voltage (1000 V and Less) AC Power Circuits

Surge-protective devices (SPDs) intended to be installed on the load side of the service equipment connected to 50 Hz or 60 Hz ac power circuits rated at 1000 V (root mean squared [rms]) or less are the focus of this standard. Performance characteristics and standard methods for testing and rating are established for these devices, which may be composed of any combination of components. The tests in this standard are aimed at providing comparisons among the variety of SPDs available

Sponsor Committee
PE/SPDLV - Surge Protective Devices/Low Voltage
Learn More About PE/SPDLV - Surge Protective Devices/Low Voltage
Status
Active Standard
PAR Approval
2014-06-12
Superseding
C62.62-2010
Board Approval
2018-02-15
History
Published:
2018-08-14

Working Group Details

Society
IEEE Power and Energy Society
Learn More About IEEE Power and Energy Society
Sponsor Committee
PE/SPDLV - Surge Protective Devices/Low Voltage
Learn More About PE/SPDLV - Surge Protective Devices/Low Voltage
Working Group
LV3.6.6 - 3.6.6 LV AC Power Circuit Protective Devices WG
IEEE Program Manager
Christian Orlando
Contact Christian Orlando
Working Group Chair
Ronald Hotchkiss

Other Activities From This Working Group

Current projects that have been authorized by the IEEE SA Standards Board to develop a standard.


No Active Projects

Standards approved by the IEEE SA Standards Board that are within the 10-year lifecycle.


C62.72-2016
IEEE Guide for the Application of Surge-Protective Devices for Use on the Load Side of Service Equipment in Low-Voltage (1000 V or Less, 50 Hz or 60 Hz) AC Power Circuits

Guidance is provided to specifiers, users and manufacturers of surge-protective devices (SPDs) about the application considerations of SPDs to power distribution systems and associated equipment. This guide applies to SPDs to be connected to the load side of the service equipment (and main over current protective device) of 50 Hz or 60 Hz ac power circuits rated 1000 V ac or less. Information on surge origins, effects of surges, number and magnitude of surge events, location categories, power distribution system (PDS) configurations, grounding and bonding, SPD specifications, SPD ratings, SPD characteristics, SPD lifetime, interactions of SPDs with a PDS, and SPD coordination considerations are provided in the guide.

Learn More About C62.72-2016

C62.72a-2020
IEEE Guide for the Application of Surge-Protective Devices for Use on the Load Side of Service Equipment in Low-Voltage (1000 V or Less, 50 Hz or 60 Hz) AC Power Circuits--Amendment 1: SPD Disconnector Application Considerations and Coordination

The application considerations for surge-protective device disconnectors and the coordination of these devices in low-voltage ac power circuits are defined in this amendment. Application consideration details, potential issues, and recommendations are provided.

Learn More About C62.72a-2020

These standards have been replaced with a revised version of the standard, or by a compilation of the original active standard and all its existing amendments, corrigenda, and errata.


C62.62-2000
IEEE Standard Test Specifications for Surge Protective Devices for Low Voltage AC Power Circuits

This standard establishes methods for testing and measuring the performance characteristics for surge-protective devices used in low-voltage ac power circuits. Definitions are stated that apply specifically to surge-protective devices. The testing requirements are categorized into two groups, in which a minimum set of basic tests (BTs) are prescribed for all surge-protective devices within the scope of its documents, supplemented by additional tests (ATs) that might be needed to establish particular application requirements.

Learn More About C62.62-2000

C62.62-2010
IEEE Standard Test Specifications for Surge-Protective Devices (SPDs) for Use on the Load Side of the Service Equipment in Low Voltage (1000 V and less) AC Power Circuits

Surge-protective devices (SPDs) intended to be installed on the load side of the service equipment connected to 50 Hz or 60 Hz AC power circuits rated at 1000 V (root mean squared [rms]) or less are the focus of this standard. Performance characteristics and standard methods for testing and rating are established for these devices, which may be composed of any combination of components. The tests in this standard are aimed at providing comparisons among the variety of SPDs available.

Learn More About C62.62-2010

C62.72-2007
IEEE Guide for the Application of Surge Protective Devices for Low Voltage (1000 Volts or Less) AC Power Circuits

Information is provided to specifiers and users of surge-protective devices (SPDs) about the application considerations of SPDs associated with power distribution systems within North America. This guide applies to SPDs to be connected to the load side of the service entrance main over current protective device of 50 Hz or 60 Hz ac power circuits rated at 100 - 1000 V rms. The effects and side effects on the presence and operation of SPDs in low-voltage power distribution systems are described. The coordination of multiple SPDs on the same circuit is described.

Learn More About C62.72-2007

These standards have been removed from active status through a ballot where the standard is made inactive as a consensus decision of a balloting group.


No Inactive-Withdrawn Standards

These standards are removed from active status through an administrative process for standards that have not undergone a revision process within 10 years.


No Inactive-Reserved Standards
Subscribe to our Newsletter

Sign up for our monthly newsletter to learn about new developments, including resources, insights and more.