Active Standard

IEEE C62.44-2016

IEEE Guide for the Application of Low-Voltage (1000 V rms or Less) Surge Protective Devices Used on Secondary Distribution Systems (Between the Transformer Low-Voltage Terminals and the Line Side of the Service Equipment)

This guide encompasses the application of surge protective devices (secondary arresters) from the secondary terminals of the distribution transformer to the line side of the service equipment.

Standard Committee
PE/SPDLV - Surge Protective Devices/Low Voltage
Status
Active Standard
PAR Approval
2012-02-06
Board Approval
2016-12-07
History
ANSI Approved:
2018-05-18
Published:
2017-02-17

Working Group Details

Society
IEEE Power and Energy Society
Standard Committee
PE/SPDLV - Surge Protective Devices/Low Voltage
Working Group
LV3.6.9 - 3.6.9 Performance Standard for LV Surge-Protective Devices (Secondary Arresters) WG
IEEE Program Manager
Christian Orlando
Contact Christian Orlando
Working Group Chair
Ray Hill

Other Activities From This Working Group

Current projects that have been authorized by the IEEE SA Standards Board to develop a standard.


No Active Projects

Standards approved by the IEEE SA Standards Board that are within the 10-year lifecycle.


C62.34-2017
IEEE Standard for Test Methods and Performance of Low-Voltage (1000 V rms or Less) Surge Protective Devices Used on Secondary Distribution Systems (Between the Transformer Low-Voltage Terminals and the Line Side of the Service Equipment)

This standard applies to surge protective devices designed for application on the low-voltage supply mains (1000 V rms and less, frequency between 48 Hz and 62 Hz) and intended to be connected at locations between, and including, the secondary terminals of the distribution transformer and the line side of the service equipment. Such surge protective devices are also known as secondary arresters. This is coordinated with IEEE Std C62.44 (the application guide), NEC Article 285, and ANSI/UL 1449.

Learn More About C62.34-2017

These standards have been replaced with a revised version of the standard, or by a compilation of the original active standard and all its existing amendments, corrigenda, and errata.


C62.34-1996
IEEE Standard for Performance of Low-Voltage Surge-Protective Devices (Secondary Arresters)

Surge-protective devices designed for application on the low-voltage ac supply mains (1000 V rms and less, frequency between 48 Hz and 62 Hz) are covered.

Learn More About C62.34-1996

These standards have been removed from active status through a ballot where the standard is made inactive as a consensus decision of a balloting group.


No Inactive-Withdrawn Standards

These standards are removed from active status through an administrative process for standards that have not undergone a revision process within 10 years.


No Inactive-Reserved Standards
Subscribe to our Newsletter

Sign up for our monthly newsletter to learn about new developments, including resources, insights and more.