IEEE Draft Standard Requirements for Secondary Network Protectors

The performance, electrical and mechanical interchangeability, and the safety of the equipment are covered. The proper selection of such equipment is established as a basis for use in this standard. Certain electrical, dimensional, and mechanical characteristics are described; and certain safety features of three-phase, 60 Hz, low-voltage (600 V and below) network protectors are taken into consideration. This equipment is used for automatically connecting and disconnecting a network transformer from a secondary spot or grid network.

Standard Committee
PE/TR - Transformers
Status
Active PAR
PAR Approval
2015-03-26
Superseding
C57.12.44-2014

Working Group Details

Society
IEEE Power and Energy Society
Standard Committee
PE/TR - Transformers
Working Group
WGC57.12.44 - STNP - Underground TR & NW Protect - Std. Req. for Sec. Network Protectors Working Group
IEEE Program Manager
Patrycja Jarosz
Contact Patrycja Jarosz
Working Group Chair
Mark Faulkner

Other Activities From This Working Group

Current projects that have been authorized by the IEEE SA Standards Board to develop a standard.


No Active Projects

Standards approved by the IEEE SA Standards Board that are within the 10-year lifecycle.


C57.12.44-2014
IEEE Standard Requirements for Secondary Network Protectors

The performance, electrical and mechanical interchangeability, and the safety of the equipment are covered. The proper selection of such equipment is established as a basis for use in this standard. Certain electrical, dimensional, and mechanical characteristics are described; and certain safety features of three-phase, 60 Hz, low-voltage (600 V and below) network protectors are taken into consideration. This equipment is used for automatically connecting and disconnecting a network transformer from a secondary spot or grid network.

Learn More About C57.12.44-2014

These standards have been replaced with a revised version of the standard, or by a compilation of the original active standard and all its existing amendments, corrigenda, and errata.


C57.12.44-2000
IEEE Standard Requirements for Secondary Network Protectors

Superseded by IEEE Std C57.12.44-2005. The performance, electrical and mechanical interchangeability, and the safety of the equipment are covered. The proper selection of such equipment is established as a basis for use in this standard. Certain electrical, dimensional, and mechanical characteristics are described; and certain safety features of three-phase, 60 Hz, low-voltage (600 V and below) network protectors are taken into consideration. This equipment is used for automatically connecting and disconnecting a network transformer from a secondary spot or grid network.

Learn More About C57.12.44-2000

C57.12.44-2005
IEEE Standard Requirements for Secondary Network Protectors

Revision of IEEE Std C57.12.44-2000. The performance, electrical and mechanical interchangeability, and the safety of the equipment are covered. The proper selection of such equipment is established as a basis for use in this standard. Certain electrical, dimensional, and mechanical characteristics are described; and certain safety features of three-phase, 60 Hz, low-voltage (600 V and below) network protectors are taken into consideration. This equipment is used for automatically connecting and disconnecting a network transformer from a secondary spot or grid network.

Learn More About C57.12.44-2005

These standards have been removed from active status through a ballot where the standard is made inactive as a consensus decision of a balloting group.


No Inactive-Withdrawn Standards

These standards are removed from active status through an administrative process for standards that have not undergone a revision process within 10 years.


No Inactive-Reserved Standards
Subscribe to our Newsletter

Sign up for our monthly newsletter to learn about new developments, including resources, insights and more.