Small power transformers have become a significant element in distribution systems supplying large commercial customers like major resort hotels and site-specific industrial customers that desire the local utility to own, operate, and maintain the serving transformer. These transformers can range in sizes from 112.5 kVA to 10 000 kVA with primary voltages at 69 000 V and below and secondary voltages from 34 500 V to 120 V. Transformers in this standard are generally for larger distribution customers often with special voltages or installation requirements like convention centers with large chiller plants and extensive exhibit space. There is often a desire to serve these transformers from underground systems using side-mounted bushings on the primary. This standard seeks to define the small power transformer that is applied as more than just a limited-scope version of the power transformers covered by IEEE Std C57.12.10™ and as more than a large distribution-class transformer covered by IEEE Std C57.12.34™.
- Standard Committee
- PE/TR - Transformers
- Status
- Active Standard
- PAR Approval
- 2011-12-07
- Superseding
- C57.12.36-2007
- Board Approval
- 2017-06-15
- History
-
- ANSI Approved:
- 2019-04-03
- Published:
- 2017-08-31
Working Group Details
- Society
- IEEE Power and Energy Society
- Standard Committee
- PE/TR - Transformers
- Working Group
-
WGC57.12.36 - Distribution - Dist. Sub. Xfrmers Working Group
- IEEE Program Manager
- Patrycja Jarosz
Contact Patrycja Jarosz - Working Group Chair
- Jerry Murphy
Other Activities From This Working Group
Current projects that have been authorized by the IEEE SA Standards Board to develop a standard.
PC57.12.36
Standard Requirements for Liquid-Immersed Distribution Substation Transformers
This standard covers certain electrical, dimensional, and mechanical characteristics of 50 Hz and 60 Hz, two winding, liquid-immersed distribution substation transformers. Such transformers may be remotely or integrally associated with either primary and secondary switchgear or substations, or both, for step-down or step-up purposes rated as follows: a) 112.5 kVA through 10 000 kVA three-phase; b) 250 kVA through 6667 kVA single-phase; c) High voltage 69 000 V and below, and low voltage 34 500 V and below. It is not intended that this standard apply to dry-type, regulating, pad-mounted, secondary-network, furnace, rectifier, mobile, railway, or mine transformers.
Standards approved by the IEEE SA Standards Board that are within the 10-year lifecycle.
No Active Standards
These standards have been replaced with a revised version of the standard, or by a compilation of the original active standard and all its existing amendments, corrigenda, and errata.
C57.12.36-2007
IEEE Standard Requirements for Liquid-Immersed Distribution Substation Transformers
Small power transformers have become a significant element in distribution systems supplying large commercial customers like major resort hotels and site-specific industrial customers that desire the local utility to own, operate, and maintain the serving transformer. These transformers can range in sizes from 112.5 kVA to 10 000 kVA with primary voltages at 69 000 V and below and secondary voltages from 34 500 V to 120 V. Transformers in this standard are generally for larger distribution customers often with special voltages or installation requirements like convention centers with large chiller plants and extensive exhibit space. There is often a desire to serve these transformers from underground systems using side-mounted bushings on the primary. This standard seeks to define the small power transformer that is applied as more than just a limited scope version of the power transformers covered by IEEE Std C57.12.10 and as more than a large distribution class transformer covered by IEEE Std C57.12.34.
These standards have been removed from active status through a ballot where the standard is made inactive as a consensus decision of a balloting group.
No Inactive-Withdrawn Standards
These standards are removed from active status through an administrative process for standards that have not undergone a revision process within 10 years.
No Inactive-Reserved Standards