Active PAR

PC57.12.10

Standard Requirements for Liquid-Immersed Power Transformers

This voluntary consensus standard sets forth the requirements for power transformer application. This standard is intended to be used as a basis for performance, interchangeability, and safety of the equipment covered, and to assist in the proper selection of such equipment. This document is a product standard that covers certain electrical, dimensional, and mechanical characteristics of 50 Hz and 60 Hz liquid-immersed power transformers base rated as follows: 833 kVA and above single-phase, 750 kVA and above three-phase. This standard applies to all liquid-immersed power transformers that do not belong to the following types of apparatus: a) Instrument transformers b) Step voltage regulators c) Arc-furnace transformers d) Rectifier transformers e) Specialty transformers f) Grounding transformers g) Mobile transformers h) Mine transformers

Sponsor Committee
PE/TR - Transformers
Learn More About PE/TR - Transformers
Status
Active PAR
PAR Approval
2024-09-26
Superseding
C57.12.10-2017

Working Group Details

Society
IEEE Power and Energy Society
Learn More About IEEE Power and Energy Society
Sponsor Committee
PE/TR - Transformers
Learn More About PE/TR - Transformers
Working Group
WGC57.12.10 - Power Transformers - Req. for Liq. Imm. Power Xfrmrs Working Group
IEEE Program Manager
Patrycja Jarosz
Contact Patrycja Jarosz
Working Group Chair
Scott Digby

Other Activities From This Working Group

Current projects that have been authorized by the IEEE SA Standards Board to develop a standard.


No Active Projects

Standards approved by the IEEE SA Standards Board that are within the 10-year lifecycle.


C57.12.10-2017
IEEE Standard Requirements for Liquid-Immersed Power Transformers

This voluntary consensus standard sets forth the requirements for power transformer application. This standard is intended to be used as a basis for performance, interchangeability, and safety of the equipment covered, and to assist in the proper selection of such equipment. This document is a product standard that covers certain electrical, dimensional, and mechanical characteristics of 50 Hz and 60 Hz, liquid-immersed power transformers and autotransformers. Such power transformers may be remotely or integrally associated with either primary switchgear or substations, or both, for step-down or step-up purposes and base rated as follows: 833 kVA and above single-phase, 750 kVA and above three-phase.This standard applies to all liquid-immersed power transformers and autotransformers that do not belong to the following types of apparatus: instrument transformers, step voltage and induction voltage regulators, arc-furnace transformers, rectifier transformers, specialty transformers, grounding transformers, mobile transformers, and mine transformers.

Learn More About C57.12.10-2017

These standards have been replaced with a revised version of the standard, or by a compilation of the original active standard and all its existing amendments, corrigenda, and errata.


C57.12.10-1997
American National Standard for Transformers-230 kV and Below 833 / 958 through 8333 / 10 417 kVA, Single-Phase, and 750 / 862 through 60 000 / 80 000 / 100 000 kVA, Three-Phase Without Load Tap Changing; and 3750 / 4687 through 60 000 / 80 000 / 100 000 kVA with Load Tap Changing-Safety Requirement

This standard covers certain electrical, dimensional, and mechanical characteristics and takes into consideration certain safety features of 60-Hz, two-winding, liquid-immersed transformers rated as follows, and used for step-down or step-up purposes: a) 833/958 through 8333/10 417 kVA, single-phase; 750/862 through 10 000/12 500 kVA, three-phase; high voltage, 2400 through 138 000 volts; low-voltage, 480 through 36 230 volts–without load tap changing; b) 12 000/16 000/20 000 through 60 000/80 000/100 000 kVA, three-phase; high voltage, 23 000 through 230 000 volts; low voltage, 4800 through 36 230 volts–without load tap changing; c) 3750/4687 through 10 000/12 500 kVA, three-phase; high voltage, 6900 through 138 000; low voltage, 2400 through 36 230 volts–with load tap changing; d) 12 000/16 000/20 000 through 60 000/80 000/100 000 kVA, three-phase; high voltage, 23 000 through 230 000 volts; low voltage, 4800 through 36 230 volts–with load tap changing. It is not intended that this standard apply to dry-type, regulating, pad-mounted, secondary-network, furnace, rectifier, or mine transformers.

Learn More About C57.12.10-1997

C57.12.10-2010
IEEE Standard Requirements for Liquid-Immersed Power Transformers

This standard sets forth the requirements for power transformer application. This standard is intended to be used as a basis for performance, interchangeability, and safety of the equipment covered and to assist in the proper selection of such equipment. This document is a product standard that covers certain electrical, dimensional, and mechanical characteristics of 50 Hz and 60 Hz, liquid-immersed power transformers and autotransformers. Such power transformers may be remotely or integrally associated with either primary switchgear or substations, or both, for step-down or step-up purposes and base rated as follows: 833 kVA and above single-phase, 750 kVA and above three-phase. This standard applies to all liquid-immersed power transformers and autotransformers that do not belong to the following types of apparatus: instrument transformers, step voltage and induction voltage regulators, arc-furnace transformers, rectifier transformers, specialty transformers, grounding transformers, mobile transformers, and mine transformers.

Learn More About C57.12.10-2010

C57.12.10-2010/Cor 1-2012
IEEE Standard Requirements for Liquid-Immersed Power Transformers--Corrigendum 1: Correction of 5.1.9--Sudden Pressure Relay

Technical corrections to 5.1.9 of IEEE Std C57.12.10 are discussed in this corrigendum.

Learn More About C57.12.10-2010/Cor 1-2012

C57.12.10-2010/Cor 2-2013
IEEE Standard Requirements for Liquid-Immersed Power Transformers -- Corrigendum 2: Correction of A.3.2.13 Autotransformer LTC application considerations

Requirements for power transformer application are set forth in this standard. It is intended to be used as a basis for performance, interchangeability, and safety of the equipment covered and to assist in the proper selection of such equipment. This document is a product standard that covers certain electrical, dimensional, and mechanical characteristics of 50 Hz and 60 Hz, liquid-immersed power transformers and autotransformers. Such power transformers may be remotely or integrally associated with either primary switchgear or substations, or both, for step-down or step-up purposes and base rated as follows: 833 kVA and above single-phase, 750 kVA and above three-phase. This standard applies to all liquid-immersed power transformers and autotransformers that do not belong to the following types of apparatus: instrument transformers, step voltage and induction voltage regulators, arc-furnace transformers, rectifier transformers, specialty transformers, grounding transformers, mobile transformers, and mine transformers.

Learn More About C57.12.10-2010/Cor 2-2013

These standards have been removed from active status through a ballot where the standard is made inactive as a consensus decision of a balloting group.


No Inactive-Withdrawn Standards

These standards are removed from active status through an administrative process for standards that have not undergone a revision process within 10 years.


No Inactive-Reserved Standards
Subscribe to our Newsletter

Sign up for our monthly newsletter to learn about new developments, including resources, insights and more.