Superseded Standard

IEEE C37.27-1987

IEEE Standard Application Guide for Low-Voltage AC Nonintegrally Fused Power Circuit Breakers (Using Separately Mounted Current-Limiting Fuses)

Low-voltage power circuit breakers of the 600 V insulation class with separately mounted current-limiting fuses, for use on ac circuits with available short-circuit current of 200 000 A (rms symmetrical) or less, are covered. Guidance is provided respecting coordination of circuit breaker and fuse, location of fuses, open fuse trip devices, addition of fuses to existing installations, protection of connected equipment, and tested combinations of circuit breakers and fuses.

Standard Committee
PE/SWG - Switchgear
Status
Superseded Standard
Superseded by
C37.27-2008
Superseding
C37.27-1972
Board Approval
1981-05-21
History
ANSI Approved:
1986-05-30
Published:
1987-07-06
Reaffirmed:
1998-06-25

Working Group Details

Society
IEEE Power and Energy Society
Standard Committee
PE/SWG - Switchgear
Working Group
LVSD/C37.27 - C37.27 - Standard Application Guide for Low-Voltage AC Nonintegrally Fused Power Circuit Breakers (Using Separately Mounted Current-Limiting Fuses)
IEEE Program Manager
Jennifer Santulli
Contact Jennifer Santulli
Working Group Chair
Marcelo Valdes

Other Activities From This Working Group

Current projects that have been authorized by the IEEE SA Standards Board to develop a standard.


PC37.27
IEEE Draft Guide for Low-Voltage AC (635 V and below) Power Circuit Breakers Applied with Separately-Mounted Current-Limiting Fuses

Application recommendations to assist in selection of separately mounted current-limiting fuses to be installed in series with low-voltage ac power circuit breakers are provided in this guide.

Learn More About PC37.27

Standards approved by the IEEE SA Standards Board that are within the 10-year lifecycle.


C37.27-2015
IEEE Guide for Low-Voltage AC (635 V and below) Power Circuit Breakers Applied with Separately-Mounted Current-Limiting Fuses

Application recommendations to assist in selection of separately mounted current-limiting fuses to be installed in series with low-voltage ac power circuit breakers are provided in this guide.

Learn More About C37.27-2015

These standards have been replaced with a revised version of the standard, or by a compilation of the original active standard and all its existing amendments, corrigenda, and errata.


C37.27-2008
IEEE Application Guide for Low-Voltage AC Power Circuit Breakers Applied with Separately-Mounted Current-Limiting Fuses

Information to assist in selection of current-limiting fuses for use with low-voltage ac power circuit breakers with separately mounted current-limiting fuses is provided.

Learn More About C37.27-2008

These standards have been removed from active status through a ballot where the standard is made inactive as a consensus decision of a balloting group.


No Inactive-Withdrawn Standards

These standards are removed from active status through an administrative process for standards that have not undergone a revision process within 10 years.


No Inactive-Reserved Standards
Subscribe to our Newsletter

Sign up for our monthly newsletter to learn about new developments, including resources, insights and more.