IEEE Draft Standard for Metal-Enclosed Bus

Metal-enclosed (ME) bus assemblies for indoor and outdoor use are discussed in this standard. The types of assemblies covered are nonsegregated-phase bus, cable bus, segregated-phase bus, and isolated-phase bus. Rated maximum voltages of ac ME bus assemblies range from 1058 V through 52 kV with continuous-current ratings of 600 A through 26 000 A for self-cooled ratings and up to 50 000 A for forced-cooled ratings. Rated maximum voltage levels of dc ME bus assemblies range from 300 V through 3200 V with continuous-current ratings of 600 A through 15000 A. Service conditions, ratings, temperature limitations and classification of insulating materials, insulation (dielectric) withstand voltage requirements, test procedures, and application are discussed. A guide for calculating losses in isolated-phase bus is included.

Standard Committee
PE/SWG - Switchgear
Status
Active PAR
PAR Approval
2020-09-24
Superseding
C37.23-2015

Working Group Details

Society
IEEE Power and Energy Society
Standard Committee
PE/SWG - Switchgear
Working Group
SA/C37.23 - C37.23 - Standard for Metal-Enclosed Bus
IEEE Program Manager
Jennifer Santulli
Contact Jennifer Santulli
Working Group Chair
Jared Hines

Other Activities From This Working Group

Current projects that have been authorized by the IEEE SA Standards Board to develop a standard.


No Active Projects

Standards approved by the IEEE SA Standards Board that are within the 10-year lifecycle.


No Active Standards

These standards have been replaced with a revised version of the standard, or by a compilation of the original active standard and all its existing amendments, corrigenda, and errata.


C37.23-2003
IEEE Standard for Metal-Enclosed Bus

Metal-enclosed (ME) bus assemblies for indoor and outdoor use are covered in this standard. The types of assemblies covered are nonsegregated-phase bus, segregated-phase bus, and isolated-phase bus. Rated maximum voltages of ac ME bus assemblies range from 0.635 kV through 38 kV with continuous current ratings of 600 A through 26 000 A for self-cooled ratings and up to 40 000 A and above for force-cooled ratings. Rated maximum voltage levels of dc bus assemblies range from 300 V through 3200 V with continuous current ratings of 600 A through 12 000 A. Service conditions, ratings, temperature limitations and classification of insulating materials, insulation (dielectric) withstand voltage requirements, test procedures, and application are discussed. A guide for calculating losses in isolated-phase bus is included.

Learn More About C37.23-2003

These standards have been removed from active status through a ballot where the standard is made inactive as a consensus decision of a balloting group.


No Inactive-Withdrawn Standards

These standards are removed from active status through an administrative process for standards that have not undergone a revision process within 10 years.


C37.23-2015
IEEE Standard for Metal-Enclosed Bus

Metal-enclosed (ME) bus assemblies for indoor and outdoor use are discussed in this standard. The types of assemblies covered are nonsegregated-phase bus, cable bus, segregated-phase bus, and isolated-phase bus. Rated maximum voltages of ac ME bus assemblies range from 1058 V through 38 kV with continuous-current ratings of 600 A through 26 000 A for self-cooled ratings and up to 50 000 A for forced-cooled ratings. Rated maximum voltage levels of dc ME bus assemblies range from 300 V through 3200 V with continuous-current ratings of 600 A through 15 000 A. Service conditions, ratings, temperature limitations and classification of insulating materials, insulation (dielectric) withstand voltage requirements, test procedures, and application are discussed. A guide for calculating losses in isolated-phase bus is included.