Enclosed low-voltage dc power circuit breakers of the stationary or drawout type of one- or two-pole construction with one or more rated maximum voltages of 300 V, 325 V, 600 V, 800 V, 1000 V, 1200 V, 1600 V, or 3200 V for applications on dc systems having nominal voltages of 250 V, 275 V, 500 V, 750 V, 850 V, 1000 V, 1500 V, or 3000 V, with general-purpose, high-speed, semi-high-speed and rectifier circuit breakers; manually or power-operated; and with or without electromechanical or electronic trip devices are covered in this standard. Service conditions, ratings, functional components, temperature limitations and classification of insulating materials, dielectric withstand voltage requirements, test procedures, and application are dealt with in this standard.
- Standard Committee
- PE/SWG - Switchgear
- Joint Sponsors
-
VT/TPSSC
- Status
- Active PAR
- PAR Approval
- 2023-02-15
- Superseding
- C37.14-2015
Working Group Details
- Society
- IEEE Power and Energy Society
- Standard Committee
- PE/SWG - Switchgear
- Working Group
-
LVSD/C37.14 - C37.14 - Standard for DC (3200 V and below) Power Circuit Breakers Used in Enclosures
- IEEE Program Manager
- Jennifer Santulli
Contact Jennifer Santulli - Working Group Chair
- Lou Grahor
Other Activities From This Working Group
Current projects that have been authorized by the IEEE SA Standards Board to develop a standard.
No Active Projects
Standards approved by the IEEE SA Standards Board that are within the 10-year lifecycle.
C37.14-2015
IEEE Standard for DC (3200 V and below) Power Circuit Breakers Used in Enclosures
Enclosed dc power circuit breakers of the stationary or drawout 32 type of one- or two-pole construction with one or more rated maximum voltages of 300 V, 325 V, 33 600 V, 800 V, 1000 V, 1200 V, 1600 V, or 3200 V for applications on dc systems having nominal 34 voltages of 250 V, 275 V, 500 V, 750 V, 850 V, 1000 V, 1500 V, or 3000 V, with general-purpose, 35 high-speed, semi-high-speed and rectifier circuit breakers; manually or power-operated; and with 36 or without electromechanical or electronic trip devices are covered in this standard. Service conditions, ratings, 37 functional components, temperature limitations and classification of insulating materials, dielectric 38 withstand voltage requirements, test procedures, and application are dealt with in this standard.
These standards have been replaced with a revised version of the standard, or by a compilation of the original active standard and all its existing amendments, corrigenda, and errata.
C37.14-2002
IEEE Standard for Low-Voltage DC Power Circuit Breakers Used in Enclosures
Reaffirmed 2008. Revision of IEEE Std C37.14-1999. This IEEE Standards product is part of the C37 family on Switchgear, Substations and Protective Relays. Abstract:This standard covers enclosed low-voltage dc power circuit breakers of the stationary or draw-out type of one- or two-pole construction with one or more rated maximum voltages of 300 V, 325 V, 800 V, 1000 V, 1200 V, 1600 V, or 3200 V for applications on dc systems having nominal voltages of 250 V, 275 V, 750 V, 850 V, 1000 V, 1500 V, or 3000 V, with general-purpose, high-speed, semi-high-speed and rectifier circuit breakers; manually or power-operated; and with or without electromechanical or electronic trip devices. It deals with service conditions, ratings, functional components, temperature limitations and classification of insulating materials, dielectric withstand voltage requirements, test procedures, and application.
These standards have been removed from active status through a ballot where the standard is made inactive as a consensus decision of a balloting group.
No Inactive-Withdrawn Standards
These standards are removed from active status through an administrative process for standards that have not undergone a revision process within 10 years.
No Inactive-Reserved Standards