This amendment to IEEE Std C37.13.1-2006 revises the short-circuit rating and test requirements for definite-purpose switching devices for use in metal-enclosed low-voltage power circuit breaker switchgear.
- Sponsor Committee
- PE/SWG - Switchgear
Learn More About PE/SWG - Switchgear - Status
- Superseded Standard
- PAR Approval
- 2008-12-10
- Board Approval
- 2010-06-17
- History
-
- ANSI Approved:
- 2011-06-24
- Published:
- 2010-08-03
Working Group Details
- Society
- IEEE Power and Energy Society
Learn More About IEEE Power and Energy Society - Sponsor Committee
- PE/SWG - Switchgear
Learn More About PE/SWG - Switchgear - Working Group
-
LVSD/C37.13.1 - C37.13.1 - Standard for Definite Purpose Switching Devices for Use in Metal-Enclosed Low-Voltage Power Circuit Breaker Switchgear
- IEEE Program Manager
- Jennifer Santulli
Contact Jennifer Santulli - Working Group Chair
- Danish Zia
Other Activities From This Working Group
Current projects that have been authorized by the IEEE SA Standards Board to develop a standard.
No Active Projects
Standards approved by the IEEE SA Standards Board that are within the 10-year lifecycle.
C37.13.1-2016
IEEE Standard for Definite-Purpose Switching Devices for Use in Metal-Enclosed Low-Voltage (600 V AC and Below) Power Circuit Breaker Switchgear
Definite-purpose switching devices for use in metal-enclosed low-voltage power circuit breaker switchgear are covered in this standard. The switching devices are fused, drawout type, three-pole construction, with one or more rated maximum ac voltages of 600 V, 508 V, and 254 V for application on systems having nominal ac voltages of 600 V, 480 V, and 240 V. The switching devices are power operated with integral or separately mounted overcurrent protective devices. Service conditions, ratings, functional components, temperature limitations and classifications of insulating materials, insulation (dielectric) withstand voltage requirements, test procedures, and application are addressed in this standard. The switching devices are normally used in applications that require frequency of operation greater than normal operations expected of low-voltage power circuit breakers.
These standards have been replaced with a revised version of the standard, or by a compilation of the original active standard and all its existing amendments, corrigenda, and errata.
C37.13.1-2006
IEEE Standard for Definite Purpose Switching Devices for Use in Metal-Enclosed Low-Voltage Power Circuit Breaker Switchgear
This standard covers definite purpose switching devices for use in metal-enclosed low-voltage power circuit breaker switchgear. The switching devices shall be fused, drawout type, three-pole construction, with one or more rated maximum ac voltages of 600 V, 508 V, and 254 V for application on systems having nominal ac voltages of 600 V, 480 V, and 240 V. The switching devices are power operated with integral or separately mounted overcurrent protective devices. This standard addresses service conditions, ratings, functional components, temperature limitations and classifications of insulating materials, insulation (dielectric) withstand voltage requirements, test procedures, and application. The switching devices are normally used in applications that require frequency of operation greater than normal operations expected of low-voltage power circuit breakers.