Superseded Standard

IEEE C37.013-1997

IEEE Standard for AC High-Voltage Generator Circuit Breakers Rated on a Symmetrical Current Basis

Ratings, performance requirements, and compliance test methods are provided for ac high-voltage generator circuit breakers rated on a symmetrical current basis that are installed between the generator and the transformer terminals. Guidance for applying generator circuit breakers is given. Pumped storage installations are considered a special application, and their requirements are not completely covered by this standard.

Sponsor Committee
PE/SWG - Switchgear
Learn More About PE/SWG - Switchgear
Status
Superseded Standard
Superseded by
62271-37-013-2015
Superseding
C37.013-1993
Amendment
C37.013a-2007
Board Approval
1997-03-20
History
ANSI Approved:
2009-03-05
Published:
1997-12-05
Reaffirmed:
2008-09-26

Additional Resources

Interpretation
C37.013-1997_interp.pdf

Working Group Details

Society
IEEE Power and Energy Society
Learn More About IEEE Power and Energy Society
Sponsor Committee
PE/SWG - Switchgear
Learn More About PE/SWG - Switchgear
Working Group
HVCB/C37.013 - C37.013 - AC High-Voltage Generator Circuit Breakers Rated on a Symmetrical Current Basis
IEEE Program Manager
Jennifer Santulli
Contact Jennifer Santulli
Working Group Chair
Mirko Palazzo

Other Activities From This Working Group

Current projects that have been authorized by the IEEE SA Standards Board to develop a standard.


P62271-37-013-2021/Cor 1
IEEE/IEC Draft International Standard for High-voltage Switchgear and Controlgear--Part 37-013: Alternating current generator circuit-breakers - Corrigendum 1

This part of IEC 62271 is applicable to three-phase AC high-voltage generator circuit breakers, hereafter called generator circuit-breakers, designed for indoor or outdoor installation and for operation at frequencies of 50 Hz and 60 Hz on systems having voltages above 1 kV and up to 38 kV. It is applicable to generator circuit-breakers that are installed between the generator and the transformer terminals. Requirements relative to generator circuit-breakers intended for use with generators and transformers rated 10 MVA or more are covered specifically. Generator circuits rated less than 10 MVA and pumped-storage installations are considered special applications, and their requirements are not completely covered by this document. This document is also applicable to the operating mechanisms of generator circuit-breakers and to their auxiliary equipment.

Learn More About P62271-37-013-2021/Cor 1

Standards approved by the IEEE SA Standards Board that are within the 10-year lifecycle.


62271-37-013-2021
IEEE/IEC International Standard for High-voltage switchgear and controlgear--Part 37-013: Alternating current generator circuit-breakers

This part of IEC 62271 is applicable to three-phase AC high-voltage generator circuit-breakers, hereafter called generator circuit-breakers, designed for indoor or outdoor installation and for operation at frequencies of 50 Hz and 60 Hz on systems having voltages above 1 kV and up to 38 kV. It is applicable to generator circuit-breakers that are installed between the generator and the transformer terminals. Requirements relative to generator circuit-breakers intended for use with generators and transformers rated 10 MVA or more are covered specifically. Generator circuits rated less than 10 MVA and pumped-storage installations are considered special applications, and their requirements are not completely covered by this document. This document is also applicable to the operating mechanisms of generator circuit-breakers and to their auxiliary equipment.

Learn More About 62271-37-013-2021

These standards have been replaced with a revised version of the standard, or by a compilation of the original active standard and all its existing amendments, corrigenda, and errata.


62271-37-013-2015
IEEE/IEC International Standard for High-voltage switchgear and controlgear -- Part 37-013: Alternating-current generator circuit-breakers

Supersedes IEEE C37.013-1997, and IEC/IEEE 62271-37-013-2015/Cor1-2017.

Learn More About 62271-37-013-2015

62271-37-013-2015/Cor 1-2017
IEEE/IEC International Standard for high-voltage switchgear and controlgear - Part 37-013: Alternating current generator circuit-breakers: Corrigendum 1

This part of IEC 62271 is applicable to three-phase a.c. high-voltage generator circuit-breakers, hereafter called generator circuit-breaker, designed for indoor or outdoor installation and for operation at frequencies of 50 Hz and 60 Hz on systems having voltages above 1 kV and up to 38 kV. It is applicable to generator circuit-breakers that are installed between the generator and the transformer terminals. Requirements relative to generator circuit-breakers intended for use with generators and transformers rated 10 MVA or more are covered specifically. Generator circuits rated less than 10 MVA and pumped storage installations are considered special applications, and their requirements are not completely covered by this standard. This standard is also applicable to the operating mechanisms of generator circuit-breakers and to their auxiliary equipment.

Learn More About 62271-37-013-2015/Cor 1-2017

These standards have been removed from active status through a ballot where the standard is made inactive as a consensus decision of a balloting group.


No Inactive-Withdrawn Standards

These standards are removed from active status through an administrative process for standards that have not undergone a revision process within 10 years.


No Inactive-Reserved Standards
Subscribe to our Newsletter

Sign up for our monthly newsletter to learn about new developments, including resources, insights and more.