Superseded Standard

IEEE 95-1977

IEEE Recommended Practice for Insulation Testing of Large AC Rotating Machinery with High Direct Voltage

Recommendations are made to aid in the selection of metric units, so as to promote uniformity in the use of metric units and to limit the number of different metric units that will be used in electrical and electronics science and technology. The recommendations can cover units for space and time, periodic and related phenomena, mechanics, heat, electricity and magnetism, light and related electromagnetic radiations, and acoustics. This document does not cover how metric units are to be used nor does it offer guidance concerning correct metric practice.

Standard Committee
PE/EM - Electric Machinery
Status
Superseded Standard
Superseded by
95-2002
Board Approval
1974-09-05
History
ANSI Approved:
1992-04-20
Published:
1977-04-29
Reaffirmed:
1991-09-26

Working Group Details

Society
IEEE Power and Energy Society
Standard Committee
PE/EM - Electric Machinery

Other Activities From This Working Group

Current projects that have been authorized by the IEEE SA Standards Board to develop a standard.


P95
IEEE Draft Recommended Practice for Insulation Testing of AC Electric Machinery With High Direct Voltage

This recommended practice provides uniform methods for testing insulation with high direct voltage, specifically form-wound windings of rotating ac electric machines typically rated 2300 V or higher. Recommendations for both (a) routine maintenance or repair testing of a machine that has been in service and (b) acceptance testing of new equipment in the factory or in the field after installation where DC testing is selected are defined.

Learn More About P95

Standards approved by the IEEE SA Standards Board that are within the 10-year lifecycle.


No Active Standards

These standards have been replaced with a revised version of the standard, or by a compilation of the original active standard and all its existing amendments, corrigenda, and errata.


No Superseded Standards

These standards have been removed from active status through a ballot where the standard is made inactive as a consensus decision of a balloting group.


No Inactive-Withdrawn Standards

These standards are removed from active status through an administrative process for standards that have not undergone a revision process within 10 years.


95-2002
IEEE Recommended Practice for Insulation Testing of AC Electric Machinery (2300 V and Above) With High Direct Voltage

This recommended practice provides information on the use of high direct voltage for proof tests and for periodic diagnostic tests on the ground wall insulation of stator (armature) windings in ac electric machines.

Learn More About 95-2002