This standard applies to high-efficiency TEFC, horizontal and vertical, single-speed, squirrel cage polyphase induction motors up to and including 500 hp, in NEMA frame sizes 143T and larger, for petroleum, chemical, and other severe duty applications (commonly referred to as severe duty motors). Excluded from the scope of this standard are motors with sleeve bearings and additional specific features required for explosion-proof motors.
- Standard Committee
- IAS/PCI - Petroleum and Chemical Industry
- Status
- Superseded Standard
- PAR Approval
- 1998-03-19
- Superseded by
- 841-2009
- Superseding
- 841-1994
- Board Approval
- 2001-03-17
- History
-
- Published:
- 2001-06-11
Working Group Details
- Society
- IEEE Industry Applications Society
- Standard Committee
- IAS/PCI - Petroleum and Chemical Industry
- Working Group
-
841_WG - Totally Enclosed Fan-Cooled (TEFC) Squirrel Cage Induction Motors Working Group
- IEEE Program Manager
- Michael Kipness
Contact Michael Kipness - Working Group Chair
- Donald Dunn
Other Activities From This Working Group
Current projects that have been authorized by the IEEE SA Standards Board to develop a standard.
No Active Projects
Standards approved by the IEEE SA Standards Board that are within the 10-year lifecycle.
841-2021
IEEE Standard for Petroleum and Chemical Industry--Premium-Efficiency, Severe-Duty, Totally Enclosed Squirrel Cage Induction Motors from 0.75 kW to 370 kW (1 hp to 500 hp)
This standard applies to premium-efficiency totally enclosed fan-cooled (TEFC) and totally enclosed nonventilated (TENV), horizontal and vertical, single-speed, squirrel cage polyphase induction motors, 0.75 kW to 370 kW (1 hp to 500 hp), and up to 4000 V nominal, in National Electrical Manufacturers Association (NEMA) frame sizes 143T and larger, for petroleum, chemical, and other severe-duty applications (commonly referred to as premium-efficiency severe-duty motors). Excluded from the scope of this standard are motors with sleeve bearings and additional specific features required for explosion-proof motors.
These standards have been replaced with a revised version of the standard, or by a compilation of the original active standard and all its existing amendments, corrigenda, and errata.
841-2009
IEEE Standard for Petroleum and Chemical Industry--Premium-Efficiency, Severe-Duty, Totally Enclosed Fan-Cooled (TEFC) Squirrel Cage Induction Motors--Up to and Including 370 kW (500 hp)
This standard applies to premium efficiency totally enclosed fan-cooled (TEFC), horizontal and vertical, single-speed, squirrel cage polyphase induction motors, up to and including 370 kW (500 hp), and 4000 volts in National Electrical Manufacturers Association (NEMA) frame sizes 143T and larger, for petroleum, chemical, and other severe duty applications (commonly referred to as premium efficiency severe duty motors). Excluded from the scope of this standard are motors with sleeve bearings and additional specific features required for explosion-proof motors.
These standards have been removed from active status through a ballot where the standard is made inactive as a consensus decision of a balloting group.