This part of IEC/IEEE 62582 contains methods for condition monitoring of optical fibres and cables in instrumentation and control systems using optical time domain reflectometer (OTDR) measurements in the detail necessary to produce accurate and reproducible results. It includes requirements for the measurement system, conditions, and reporting of measured results. The parts of IEC/IEEE 62582 are measurement standards, primarily for use in the management of ageing during initial qualification and after installation. IEC/IEEE 62582-1 includes requirements for the application of the other parts of IEC/IEEE 62582 and some elements which are common to all methods. Information on the role of condition monitoring for qualification of equipment important to safety is found in IEC/IEEE 60780-323. Detailed measurement methods of attenuation are provided in IEC 61280-4-1 for multimode fibre optic cables and in IEC 61280-4-2 for single-mode fibre optic cables.
- Standard Committee
- PE/NPEC - Nuclear Power Engineering Committee
- Status
- Active PAR
- PAR Approval
- 2024-09-26
- Superseding
- 62582-5-2015
Working Group Details
- Society
- IEEE Power and Energy Society
- Standard Committee
- PE/NPEC - Nuclear Power Engineering Committee
- Working Group
-
WG2.17 - Conditioning Monitoring WG
- IEEE Program Manager
- Christian Orlando
Contact Christian Orlando - Working Group Chair
- Eric Rasmussen
Other Activities From This Working Group
Current projects that have been authorized by the IEEE SA Standards Board to develop a standard.
No Active Projects
Standards approved by the IEEE SA Standards Board that are within the 10-year lifecycle.
62582-1-2024
IEEE International Standard for Nuclear power plants -- Instrumentation and control important to safety--Electrical equipment condition monitoring methods--Part 1: General
This part of the IEC/IEEE 62582 series contains requirements for application of the other parts of IEC/IEEE 62582 related to specific methods for condition monitoring in electrical equipment important to safety of nuclear power plants. It also includes requirements which are common to all methods. The procedures defined in IEC/IEEE 62582 are intended for detailed condition monitoring. IEC/IEEE 62582 specifies condition monitoring methods in sufficient detail to enhance the accuracy and repeatability, and provide standard formats for reporting the results. The methods specified are applicable to electrical equipment containing polymeric materials. Some methods are especially designed for the measurement of condition of a limited range of equipment whilst others can be applied to all types of equipment for which the polymeric parts are accessible. Although the scope of IEC/IEEE 62582 is limited to the application of instrumentation and control systems important to safety, the condition monitoring methods can also be applicable to other components which include polymeric materials. The different parts of IEC/IEEE 62582 are measurement standards, primarily for use in the management of ageing in initial qualification and after installation. For the technical background of condition monitoring methods, reference is made to other IEC standards, e.g. IEC 60544-5 [1]. Information on the role of condition monitoring in qualification of electrical equipment important to safety is found in IEC/IEEE 60780-323. General information on management of ageing can be found in IEC 62342 [5] and IEEE 1205 [6].
62582-2-2022
IEC/IEEE International Standard - Nuclear power plants - Instrumentation and control important to safety - Electrical equipment condition monitoring methods - Part 2: Indenter measurements
This standard contains both English and French
62582-3-2024
IEC/IEEE International Standard for Nuclear Power Plants - Instrumentation and control important to safety - Electrical equipment condition monitoring methods - Part 3: Elongation at break
This standard contains both English and French
62582-4-2022
IEC/IEEE International Standard - Nuclear power plants - Instrumentation and control important to safety - Electrical equipment condition monitoring methods - Part 4: Oxidation induction techniques
This standard contains both English and French
These standards have been replaced with a revised version of the standard, or by a compilation of the original active standard and all its existing amendments, corrigenda, and errata.
No Superseded Standards
These standards have been removed from active status through a ballot where the standard is made inactive as a consensus decision of a balloting group.
No Inactive-Withdrawn Standards
These standards are removed from active status through an administrative process for standards that have not undergone a revision process within 10 years.
62582-1-2011
Nuclear power plants - Instrumentation and control important to safety - Electrical equipment condition monitoring methods - Part 1: General
IEC/IEEE 62582-1:2011 contains requirements for application of the other parts of IEC/IEEE 62582 related to specific methods for condition monitoring in electrical equipment important to safety of nuclear power plants. It also includes requirements which are common to all methods.