Active Standard

IEEE/IEC 62209-1528-2020

IEC/IEEE International Standard - Measurement procedure for the assessment of specific absorption rate of human exposure to radio frequency fields from hand-held and body-mounted wireless communication devices - Part 1528: Human models, instrumentation, and procedures (Frequency range of 4 MHz to 10 GHz)

Replaces IEC 62209-1:2016, IEC 62209-2:2010, and IEEE Std 61528:2013 and supersedes IEEE Std 1528-2013

Sponsor Committee
BOG/ICES - International Committee on Electromagnetic Safety
Learn More About BOG/ICES - International Committee on Electromagnetic Safety
Status
Active Standard
PAR Approval
2018-05-14
Superseding
1528-2013
Proposed Amendment
P62209-1528a
Board Approval
2020-09-24
History
Published:
2020-10-19

Additional Resources

Downloads
62209-1528-2020_downloads.zip

Working Group Details

Society
IEEE SA Board of Governors
Sponsor Committee
BOG/ICES - International Committee on Electromagnetic Safety
Learn More About BOG/ICES - International Committee on Electromagnetic Safety
Working Group
P62209-3 - Measurement procedure for the assessment of specific absorption rate of human exposure to radio frequency fields from hand-held and body-mounted wireless communication devices - Part 3: Vector measurement-based systems (Frequency range of 600 MHz to 6 GHz)
IEEE Program Manager
Patricia Roder
Contact Patricia Roder
Working Group Chair
Teruo Onishi

Other Activities From This Working Group

Current projects that have been authorized by the IEEE SA Standards Board to develop a standard.


No Active Projects

Standards approved by the IEEE SA Standards Board that are within the 10-year lifecycle.


1528.7-2020
IEEE Guide for EMF Exposure Assessment of Internet of Things (IoT) Technologies and Devices

In the wireless communication field, 5G and Internet of Things (IoT) solutions are the main emerging technologies and future wireless communication will rely on them. A methodology for classifying IoT devices based on radio frequency (RF) exposure characteristics is provided. Classification is based on frequency, bandwidth, radiated power, and typical installation configuration. Links between device class and available measurement/computational standards are provided. A framework criterion for exclusion classes for exposure assessment and criteria for addressing situations where exposure assessment is unavailable are included.

Learn More About 1528.7-2020

These standards have been replaced with a revised version of the standard, or by a compilation of the original active standard and all its existing amendments, corrigenda, and errata.


1528-2013
IEEE Recommended Practice for Determining the Peak Spatial-Average Specific Absorption Rate (SAR) in the Human Head from Wireless Communications Devices: Measurement Techniques

Protocols and test procedures are specified for the measurement of the peak spatial-average SAR induced inside a simplified model of the head of users of certain handheld radio transceivers. These transceivers are intended to be used for personal wireless communications services, operate in the 300 MHz to 6 GHz frequency range, and are intended to be operated while held against the ear. The results obtained by following the protocols specified in this recommended practice represent a conservative estimate of the peak spatial-average SAR induced in the head of a significant majority of persons, subject to measurement and other uncertainties that are defined in this recommended practice. The results are representative of those expected during conditions of intended use of a handheld wireless device. It is not the intent of this recommended practice to provide a result representative of the absolute maximum SAR value possible under every conceivable combination of head size, head shape, handset orientation, and spacing relative to the head. The measurement of SAR induced in the external tissues of the head, e.g., the external ear (pinna), is not addressed in this document. This recommended practice also does not address the body SAR measurements typically required for wireless handsets. The following items are described in detail: measurement concepts, measurement techniques, instruments, calibration techniques, simulated-tissue (phantom) models, including homogeneous anatomically equivalent models of the human head and simple phantoms for validation of the SAR measurement system, and the limitations of these systems when used for measuring the spatial-peak mass-averaged SAR. Procedures for calibrating electric field (E-field) probes used for SAR measurements and assessing the SAR measurement and system uncertainties are provided in the annexes. This recommended practice is intended primarily for use by engineers and other specialists who are familiar with electromagnetic (EM) theory and SAR measurement techniques; it does not recommend specific SAR limit values since these are found in other documents. The benefits to the users include standardized and accepted protocols, validation techniques, and means for estimating the overall measurement uncertainty in order to produce valid and repeatable data.

Learn More About 1528-2013

1528a-2005
IEEE Recommended Practice for Determining the Peak Spatial-Average Specific Absorption Rate (SAR) in the Human Head from Wireless Communications Devices: Measurement Techniques - Amendment 1: CAD File for Human Head Model (SAM Phantom)

Amendment to IEEE Std 1528-2003. This amendment to IEEE Std 1528 addresses certain text ambiguities in IEEE Std 1528-2003 and provides a CAD data file for the human head model from the original project but which was not included with the original standard.

Learn More About 1528a-2005

These standards have been removed from active status through a ballot where the standard is made inactive as a consensus decision of a balloting group.


No Inactive-Withdrawn Standards

These standards are removed from active status through an administrative process for standards that have not undergone a revision process within 10 years.


No Inactive-Reserved Standards
Subscribe to our Newsletter

Sign up for our monthly newsletter to learn about new developments, including resources, insights and more.