Methods for defining the direct current (dc) load and for sizing a lead-acid battery to supply that load for stationary battery applications in full-float operations are described in this recommended practice. Some factors relating to cell selection are provided for consideration. Installation, maintenance, qualification, testing procedures, and consideration of battery types other than lead-acid are beyond the scope of this recommended practice. Design of the dc system and sizing of the battery charger(s) are also beyond the scope of this recommended practice.
- Standard Committee
- PE/ESSB - Energy Storage & Stationary Battery Committee
- Status
- Superseded Standard
- PAR Approval
- 2004-03-25
- Superseded by
- 485-2020
- Superseding
- 485-1997
- Board Approval
- 2010-11-08
- History
-
- ANSI Approved:
- 2011-09-01
- Published:
- 2011-04-15
Working Group Details
- Society
- IEEE Power and Energy Society
- Standard Committee
- PE/ESSB - Energy Storage & Stationary Battery Committee
- Working Group
-
WG_485 - Vented Lead Acid Sizing Working Group
- IEEE Program Manager
- Michael Kipness
Contact Michael Kipness - Working Group Chair
- James Midolo
Other Activities From This Working Group
Current projects that have been authorized by the IEEE SA Standards Board to develop a standard.
No Active Projects
Standards approved by the IEEE SA Standards Board that are within the 10-year lifecycle.
485-2020
IEEE Recommended Practice for Sizing Lead-Acid Batteries for Stationary Applications
Methods for defining the dc load and for sizing a lead-acid battery to supply that load for stationary battery applications in float service are described in this recommended practice. Some factors relating to cell selection are provided for consideration. Installation, maintenance, qualification, testing procedures, and consideration of battery types other than lead-acid are beyond the scope of this recommended practice. Design of the dc system and sizing of the battery charger(s) are also beyond the scope of this recommended practice.
These standards have been replaced with a revised version of the standard, or by a compilation of the original active standard and all its existing amendments, corrigenda, and errata.
485-1997
IEEE Recommended Practice for Sizing Lead-Acid Batteries for Stationary Applications
Methods for defining the dc load and for sizing a lead-acid battery to supply that load for stationary battery applications in full float operations are described. Some factors relating to cell selection are provided for consideration. Installation, maintenance, qualification, testing procedures, and consideration of battery types other than lead-acid are beyond the scope of this recommended practice. Design of the dc system and sizing of the battery charger(s) are also beyond the scope of this recommended practice. http://standards.ieee.org/reading/ieee/interp/485-1997.html
These standards have been removed from active status through a ballot where the standard is made inactive as a consensus decision of a balloting group.
No Inactive-Withdrawn Standards
These standards are removed from active status through an administrative process for standards that have not undergone a revision process within 10 years.
No Inactive-Reserved Standards