Superseded Standard

IEEE 386-1995

IEEE Standard for Separable Insulated Connector Systems for Power Distribution Systems above 600 V

Definitions, service conditions, ratings, interchangeable construction features, and tests are established for load-break and dead-break separable insulated connector systems rated 601 V and above, 600A or less, for use on power distribution systems.

Standard Committee
PE/IC - Insulated Conductors
Status
Superseded Standard
Superseded by
386-2006
Superseding
386-1985
Board Approval
1995-03-16
History
ANSI Approved:
1995-10-06
Published:
1995-11-30
Reaffirmed:
2001-03-17

Working Group Details

Society
IEEE Power and Energy Society
Standard Committee
PE/IC - Insulated Conductors

Other Activities From This Working Group

Current projects that have been authorized by the IEEE SA Standards Board to develop a standard.


No Active Projects

Standards approved by the IEEE SA Standards Board that are within the 10-year lifecycle.


386-2025
IEEE Approved Draft Standard for Shielded Separable Insulated Connectors for Classes 15 kV through 35 kV

Definitions, service conditions, ratings, interchangeable construction features, and tests are established for loadbreak and deadbreak separable insulated connector systems for use on power distribution systems rated 2.5 kV through 35 kV and 900 A or less.

Learn More About 386-2025

These standards have been replaced with a revised version of the standard, or by a compilation of the original active standard and all its existing amendments, corrigenda, and errata.


386-2006
IEEE Standard for Separable Insulated Connector Systems for Power Distribution Systems above 600 V

Revision of IEEE Std 386-2000 Definitions, service conditions, ratings, interchangeable construction features, and tests are established for loadbreak and deadbreak separable insulated connector systems rated above 600 V and, 600 A or less, for use on power distribution systems.

Learn More About 386-2006

386-2016
IEEE Standard for Separable Insulated Connector Systems for Power Distribution Systems Rated 2.5 kV through 35 kV

Definitions, service conditions, ratings, interchangeable construction features, and tests are established for loadbreak and deadbreak separable insulated connector systems for use on power distribution systems rated 2.5 kV through 35 kV and 900 A or less.

Learn More About 386-2016

These standards have been removed from active status through a ballot where the standard is made inactive as a consensus decision of a balloting group.