Superseded Standard

IEEE 252-1977

IEEE Test Procedure for Polyphase Induction Motors Having Liquid in the Magnetic Gap

This test procedure covers instructions for conducting and reporting the more generally applicable and acceptable tests to determine the performance characteristics of polyphase induction motors having liquid in the magnetic gap. Constants in several equations and forms apply to three-phase motors only and require modification for application to motors having another number of phases. It is not intended that the Procedure cover all possible tests of a research nature. The Procedure shall not be interpreted as requiring the making of any or all of the tests described herein in any given transaction.

Standard Committee
PE/EM - Electric Machinery
Status
Superseded Standard
Superseded by
252-1995
Superseding
252-1963
Board Approval
1976-06-03
History
Published:
1977-08-12

Working Group Details

Society
IEEE Power and Energy Society
Standard Committee
PE/EM - Electric Machinery

Other Activities From This Working Group

Current projects that have been authorized by the IEEE SA Standards Board to develop a standard.


No Active Projects

Standards approved by the IEEE SA Standards Board that are within the 10-year lifecycle.


252-2022
IEEE Standard Test Procedure for Polyphase Induction Motors Having Liquid in the Magnetic Gap

Instructions for conducting and reporting the generally applicable and acceptable tests to determine the performance characteristics of polyphase induction motors having liquid in the magnetic gap are given. Constants in several equations and forms apply to three-phase motors only and require modifications for applications to motors having another number of phases. It is not intended that the procedures cover all possible tests or tests of a research nature. The procedures shall not be interpreted as requiring the making of any or all tests described herein in any given transaction.

Learn More About 252-2022

These standards have been replaced with a revised version of the standard, or by a compilation of the original active standard and all its existing amendments, corrigenda, and errata.


No Superseded Standards

These standards have been removed from active status through a ballot where the standard is made inactive as a consensus decision of a balloting group.


No Inactive-Withdrawn Standards

These standards are removed from active status through an administrative process for standards that have not undergone a revision process within 10 years.


252-1995
IEEE Standard Test Procedure for Polyphase Induction Motors Having Liquid in the Magnetic Gap

In this IEEE Standard instructions for conducting and reporting the more generally applicable and acceptable tests to determine the performance characteristics of polyphase induction motors having liquid in the magnetic gap are given. Constants in several equations and forms apply to three-phase motors only and require modification for application to motors having another number of phases.

Learn More About 252-1995

Subscribe to our Newsletter

Sign up for our monthly newsletter to learn about new developments, including resources, insights and more.