This standard provides a procedure that shall be used to (1) assess structures for atmospheric corrosion; (2) assess the level of risk to the structure in terms of corrosion attack and degradation to the existing coating system; (3) make informed decisions based on those findings as to whether coating repair is needed and if so, to what extent; and (4) apply repair coatings to the structure if applicable. This standard applies to the repair of above-grade atmospheric coatings. For the purposes of this standard, the atmospheric area to be coated is generally comprised of that portion of the utility support structure above the transition zone. This standard is limited to the above-grade and atmospheric portions of utility support structures. It does not address below-grade coating repair within and below the transition zone. This standard does not address foundations or guy anchoring systems. This standard does not cover the coating of aluminum, weathering steel, concrete, or any material other than steel. Likewise, it does not cover the coating of non-support structures such as fencing, buildings, transformers, or other miscellaneous components within the transmission, distribution, and substation systems. This standard does not cover new construction, transition zone, below-grade, or water immersion. These areas of concern are addressed specifically in other NACE/IEEE standards. This standard does not address mechanical or structural damage, mechanical or structural repairs, or structural integrity.
- Standard Committee
- PE/T&D - Transmission and Distribution
- Status
- Inactive-Reserved Standard
- PAR Approval
- 2011-03-31
- Board Approval
- 2014-12-10
- History
-
- Published:
- 2015-05-01
- Inactivated Date:
- 2025-03-27
Working Group Details
- Society
- IEEE Power and Energy Society
- Standard Committee
- PE/T&D - Transmission and Distribution
- Working Group
-
TPC-Corrosion - Corrosion Working Group (NACE)
- IEEE Program Manager
- Jennifer Santulli
Contact Jennifer Santulli - Working Group Chair
- Jeff Butler
Other Activities From This Working Group
Current projects that have been authorized by the IEEE SA Standards Board to develop a standard.
P1835
Standard for Atmospheric (Above Grade) Corrosion Control of Existing Electric Transmission, Distribution, and Substation Structures by Coating Systems
This standard provides a procedure to (1) assess structures for atmospheric corrosion; (2) assess the level of risk to the structure in terms of corrosion attack and degradation to the existing coating system; (3) make informed decisions based on those findings as to whether coating repair is needed, and if so, to what extent; and (4) apply repair coatings to the structure if applicable. This standard applies to the repair of above-grade atmospheric coatings. For the purposes of this standard, the atmospheric area to be coated generally comprises of that portion of the utility support structure above the transition zone, which is that portion of the coating exposed up to 600 mm (24 in) above grade.
Standards approved by the IEEE SA Standards Board that are within the 10-year lifecycle.
No Active Standards
These standards have been replaced with a revised version of the standard, or by a compilation of the original active standard and all its existing amendments, corrigenda, and errata.
No Superseded Standards
These standards have been removed from active status through a ballot where the standard is made inactive as a consensus decision of a balloting group.
No Inactive-Withdrawn Standards
These standards are removed from active status through an administrative process for standards that have not undergone a revision process within 10 years.
No Inactive-Reserved Standards