Active PAR

IEEE P1584.2

IEEE Draft Guide and Checklists for the Data Collection for Performing an Arc-Flash Hazard Calculation Study in Accordance with IEEE Std. 1584™ and IEEE Std.1584.1™ for Systems Operating at Three-Phase 50/60 Hz Alternating Current (AC) 1000 V and below

Guidance for the checklists and collection of data required for performing an arc-flash hazard calculation study, in accordance with the process defined in IEEE Std 1584™, is provided in this document. The focus is on three-phase 50/60 Hz alternating current (ac) systems operating at 1000 V and below.

Standard Committee
IAS/PCI - Petroleum and Chemical Industry
Status
Active PAR
PAR Approval
2022-09-21

Working Group Details

Society
IEEE Industry Applications Society
Standard Committee
IAS/PCI - Petroleum and Chemical Industry
Working Group
1584_WG - Arc Flash Hazard Calculations Working Group
IEEE Program Manager
Michael Kipness
Contact Michael Kipness
Working Group Chair
Daleep Mohla

Other Activities From This Working Group

Current projects that have been authorized by the IEEE SA Standards Board to develop a standard.


No Active Projects

Standards approved by the IEEE SA Standards Board that are within the 10-year lifecycle.


1584-2018
IEEE Guide for Performing Arc-Flash Hazard Calculations

This guide provides mathematical models for designers and facility operators to apply in determining the arc-flash hazard distance and the incident energy to which workers could be exposed during their work on or near electrical equipment.

Learn More About 1584-2018

1584.1-2022
IEEE Guide for the Specification of Scope and Deliverable Requirements for an Arc-Flash Hazard Calculation Study in Accordance with IEEE Std 1584

Guidance for the specification and performance of an arc-flash hazard calculation study, in accordance with the process defined in IEEE Std 1584, is provided in this document. The minimum recommended requirements to enable the owner to specify an arc-flash hazard calculation study, including scope of work and associated deliverables, is outlined.

Learn More About 1584.1-2022

These standards have been replaced with a revised version of the standard, or by a compilation of the original active standard and all its existing amendments, corrigenda, and errata.


1584-2002
IEEE Guide for Performing Arc Flash Hazard Calculations

This guide provides techniques for designers and facility operators to apply in determining the arc flash hazard distance and the incident energy to which employees could be exposed during their work on or near electrical equipment. Included are 2 Arc Flash Hazard Calculators and 3 Test Data files. Contact [email protected] for these additional files. An interpretation is available at http://standards.ieee.org/reading/ieee/interp/1584-2002.html

Learn More About 1584-2002

1584.1-2013
IEEE Guide for the Specification of Scope and Deliverable Requirements for an Arc-Flash Hazard Calculation Study in Accordance with IEEE Std 1584(TM)

Guidance for the specification and performance of an arc-flash hazard calculation study, in accordance with the process defined in IEEE Std 1584(TM), is provided in this document. It outlines the minimum recommended requirements to enable the owner or its representative to specify an arc-flash hazard study, including scope of work and associated deliverables.

Learn More About 1584.1-2013

1584a-2004
IEEE Guide for Performing Arc-Flash Hazard Calculations--Amendment 1

Amendment to 1584-2002 This amendment provides additions and corrections to IEEE Std 1584-2002.

Learn More About 1584a-2004

1584b-2011
IEEE Guide for Performing Arc-Flash Hazard Calculations--Amendment 2: Changes to Clause 4

Techniques for designers and facility operators to apply in determining the arc-flash hazard distance and the incident energy to which employees could be exposed during their work on or near electrical equipment are provided in IEEE Std 1584-2002 and IEEE Std 1584a-2004. Changes in Clause 4 (the analysis process), based on the experience of persons who have conducted many of these studies, are provided in this amendment.

Learn More About 1584b-2011

These standards have been removed from active status through a ballot where the standard is made inactive as a consensus decision of a balloting group.


No Inactive-Withdrawn Standards

These standards are removed from active status through an administrative process for standards that have not undergone a revision process within 10 years.


No Inactive-Reserved Standards
Subscribe to our Newsletter

Sign up for our monthly newsletter to learn about new developments, including resources, insights and more.