Active Standard

IEEE 1542-2018

IEEE Guide for Installation, Maintenance, and Operation of Irrigation Equipment Located Near or Under Power Lines

Industry practices and guidelines for installation, maintenance, and operation of irrigation equipment near or under power lines as they pertain to minimum distance to energized conductors and proper grounding to help minimize nuisance shocks are presented in this guide. A variety of conditions in general terms is covered in this guide. Specific recommendations are made for the type of irrigation systems and power line parameters most commonly found.

Standard Committee
PE/T&D - Transmission and Distribution
Status
Active Standard
PAR Approval
2016-05-12
Superseding
1542-2007
Board Approval
2018-12-05
History
Published:
2019-01-11

Working Group Details

Society
IEEE Power and Energy Society
Standard Committee
PE/T&D - Transmission and Distribution
Working Group
OHL-Corona_WG - Corona and Field Effects
IEEE Program Manager
Michael Kipness
Contact Michael Kipness
Working Group Chair
Robert Schaerer

Other Activities From This Working Group

Current projects that have been authorized by the IEEE SA Standards Board to develop a standard.


P1227
Guide for the Measurement of DC Electric-Field Strength and Ion Related Quantities

This standard establishes uniform procedures for the measurement of electric-field strength, ion-current density, conductivity, monopolar space-charge density and net space-charge density in the vicinity of high-voltage dc (HVDC) sources.

Learn More About P1227

P1829
Guide for Conducting Corona Tests on Hardware Assemblies for Overhead Transmission Lines and Substations

This guide establishes uniform procedures for the testing of transmission line and station bus hardware assemblies in high voltage (>100 kV ) laboratories. Two tests are described. The first one is a corona performance test. The second is a radio interference voltage (RIV) test. The first test uses visible techniques to determine the onset of positive corona. The second test is a measurement of the RIV voltage according to ANSI C63.2 or CISPR 16-1-1 and CISPR TR 18-2. This guide does not address the permissible radio interference (RI) limits or specified corona extinction voltages. They are set either by regulation or by agreement between the end user and hardware manufacturer.

Learn More About P1829

P2819
IEEE Draft Recommended Practice for Measuring Electromagnetic Fields from Overhead Power Transmission Lines in Shared AC and DC Corridors

Uniform procedures for the measurement of the power frequency electric field and dc electric field when ac/dc power transmission lines are installed in parallel or on shared towers are established in this recommended practice. The measurement ranges and layout of measurement points, data recording and processing, and result evaluation methods of parallel power transmission lines of different voltage levels are recommended.

Learn More About P2819

Standards approved by the IEEE SA Standards Board that are within the 10-year lifecycle.


1260-2018
IEEE Guide on the Prediction,Measurement, and Analysis of AM Broadcast Reradiation by Power Lines

A set of procedures to be followed to cope with reradiation of AM broadcast signals from power lines and other large metallic structures is provided. Reradiation may be described as electromagnetic waves radiated from a structure that has parasitically picked up a signal from the environment. A simplified prediction technique called a survey is described to determine which structures could possibly cause a problem. Guidelines for measurements and data analysis are included.

Learn More About 1260-2018

1308-2023
IEEE Recommended Practice for Instrumentation: Specifications for Magnetic Flux Density and Electric Field Strength Meters–10 Hz to 3 kHz

Specifications that should be provided to characterize instrumentation used to measure the steady state root mean square (rms) value of magnetic and electric fields with sinusoidal frequency content in the range 10 Hz to 3 kHz are identified. The instrumentation, recommended calibration methods, and sources of measurement uncertainty are also described.

Learn More About 1308-2023

1829-2017
IEEE Guide for Conducting Corona Tests on Hardware for Overhead Transmission Lines and Substations

Uniform procedures for the testing of transmission line and station bus hardware in high voltage laboratories are established in this guide. Two tests are described: the first is a visual corona test, the second is a radio interference voltage (RIV) test. This guide does not address the permissible radio interference (RI) limits or specified corona extinction voltages. They are set either by regulation or by agreement between the utility and hardware manufacturer.

Learn More About 1829-2017

2746-2020
IEEE Guide for Evaluating AC Interference on Linear Facilities Co-Located Near Transmission Lines

This guide identifies the mechanisms and analytic approach for ac interference effects on conductive linear facilities due to the operation of co-located electric transmission lines. The common mechanisms for ac interference such as magnetic inductive coupling, capacitive coupling, and conductive voltage transfer through soil are discussed. Included are general guidelines and considerations for performing detailed ac interference analyses, with sections specific to the analysis of co-located pipeline and railroad facilities. This guide does not dictate specific compliance limits, direct when an ac interference analysis must be performed, or cover other issues that may need to be considered in joint-use corridors, such as effects due to lightning striking the line or dc corrosion on structures.

Learn More About 2746-2020

430-2017
IEEE Standard Procedures for the Measurement of Radio Noise from Overhead Power Lines and Substations

Uniform procedures for the measurement of radio noise generated by corona from overhead power lines and substations are established in this standard. Measurement procedures in this standard are also valid for other power-line noise sources such as gaps and harmonics; however, most of the precautionary information, analysis, and data plotting techniques were written and developed primarily for corona discharges. The procedures are not valid for measuring transient radio noise sources that occur during breaker or disconnect switching operations. The procedures apply in the frequency range of 0.010 MHz to 1000 MHz; however, the emphasis is on the standard amplitude-modulation broadcasting (0.535 MHz to 1.605 MHz) and television broadcasting (54 MHz to 72 MHz, 76 MHz to 88 MHz, 174 MHz to 216 MHz, and 470 MHz to 698 MHz) bands. This standard is applicable to both ac and dc transmission lines and substations.

Learn More About 430-2017

539-2020
IEEE Standard Definitions of Terms Relating to Corona and Field Effects of Overhead Power Lines

Definitions and usage of terms used in the measurement and analysis of corona and field effects of overhead power lines are presented in this standard. Correlation between measurements from equipment to standard terms is defined. Weather conditions such as rain, snow, and fog are defined and their measurement standards discussed. The intent is to assist in correlating standard terms found in literature and requirements to standard engineering practice.

Learn More About 539-2020

644-2019
IEEE Standard Procedures for Measurement of Power Frequency Electric and Magnetic Fields from AC Power Lines

Uniform procedures for the measurement of power frequency electric and magnetic fields from alternating current (ac) overhead power lines and for the calibration of the meters used in these measurements are established in this standard. The procedures apply to the measurement of electric and magnetic fields close to ground level. The procedures can also be tentatively applied (with limitations, as specified in the standard) to electric fields near an energized conductor or structure.

Learn More About 644-2019

656-2018
IEEE Standard for the Measurement of Audible Noise from Overhead Transmission Lines

Uniform procedures are established for manual and automatic measurement of audible noise from overhead transmission lines. Their purpose is to allow valid evaluation and comparison of the audible noise performance of various overhead lines. Definitions are provided, and instruments are specified. Measurement procedures are set forth, and precautions are given. Supporting data that should accompany the measurement data are specified, and methods for presenting the latter are described.

Learn More About 656-2018

These standards have been replaced with a revised version of the standard, or by a compilation of the original active standard and all its existing amendments, corrigenda, and errata.


1260-1996
IEEE Guide on the Prediction, Measurement, and Analysis of AM Broadcast Reradiation by Power Lines

A set of procedures to be followed to cope with reradiation of AM broadcast signals from power lines and other large metallic structures is provided. Reradiation may be described as electromagnetic waves radiated from a structure that has parasitically picked up a signal from the environment. A simplified prediction technique called a survey is described to determine which structures could possibly cause a problem. Guidelines for measurements and data analysis are included.

Learn More About 1260-1996

1542-2007
IEEE Guide for Installation, Maintenance, and Operation of Irrigation Equipment Located Near or Under Power Lines

The guide is based on industry practices, and guidelines for installation, maintenance and operation of irrigation equipment near or under power lines as they pertain to minimum distance to energized conductors and proper grounding to minimize nuisance shocks are presented. A variety of conditions in general terms is covered in this guide. Specific recommendations are made for the type of irrigation systems and power line parameters most commonly found.

Learn More About 1542-2007

430-1972
IEEE Trial Use Standard Procedures for the Measurement of Radio Noise from Overhead Power Lines

Learn More About 430-1972

430-1976
IEEE Standard Procedures for the Measurement of Radio Noise from Overhead Power Lines

Learn More About 430-1976

539-2005
IEEE Standard Definitions of Terms Relating to Corona and Field Effects of Overhead Power Lines

Definitions and usage of terms used in the measurement and analysis of corona and field effects of overhead power lines are presented in this standard. Correlation between measurements from equipment to standard terms is defined. Weather conditions such as rain, snow, fog, and drizzle are defined and their measurement standards discussed. The intent is to assist in correlating standard terms found in literature and requirements to standard engineering practice.

Learn More About 539-2005

644-1994
IEEE Standard Procedures for Measurement of Power Frequency Electric and Magnetic Fields from AC Power Lines

Uniform procedures for the measurement of power frequency electric and magnetic fields from alternating current 9ac) overhead power lines and for the calibration of the meters used in these measurements are established. The procedures apply to the measurement of electric and magnetic fields close to ground level. The procedures can also be tentatively applied (with limitations, as specified in the standard) to electric fields near an energized conductor or structure.

Learn More About 644-1994

656-1992
IEEE Standard for the Measurement of Audible Noise from Overhead Transmission Lines

Uniform procedures are established for manual and automatic measurement of audible noise from overhead transmission lines. Their purpose is to allow valid evaluation and comparison of the audible noise performance of various overhead lines. Definitions are provided, and instruments are specified. Measurement procedure are set forth, and precautions are given. Supporting data that should accompany the measurement data are specified, and methods for presenting the latter are described.

Learn More About 656-1992

These standards have been removed from active status through a ballot where the standard is made inactive as a consensus decision of a balloting group.


430-1958
AIEE Proposed Recommended Practice for Toroidal Magnetic tape Wound Cores

The scope of this recommended practice is restricted to the recommendation of nominal dimensions for torodial strip-wound cores made from magnetic tape between approximately 0.014 and 0.005 inch in thickness and without regard to the type of magnetic material used. Bobbin-wound cores of ultra-thin magnetic tapes are not included. Also excluded from consideration are recommendations on dimensional tolerances, space factors, number of wraps of tape, core case shape or size, and particular values of strip thickness.

Learn More About 430-1958

These standards are removed from active status through an administrative process for standards that have not undergone a revision process within 10 years.


1227-1990
IEEE Guide for the Measurement of DC Electric-Field Strength and Ion Related Quantities

Guidance is provided for measuring the electric-field strength, ion-current density, conductivity, monopolar space-charge density, and net space-charge density in the vicinity of HVDC power lines, in converter substations, and in apparatus designed to simulate the HVDC power-line environment.

Learn More About 1227-1990

1308-1994
IEEE Recommended Practice for Instrumentation: Specifications for Magnetic Flux Density and Electric Field Strength Meters - 10 Hz to 3 kHz

Specifications that should be provided to characterize instrumentation used to measure the steady state rms value of magnetic and electric fields with sinusoidal frequency content in the range 10 Hz to 3 kHz in residential and occupational settings as well as in transportation systems are identified. The instrumentation, recommended calibration methods, and sources of measurement uncertainty are also described.

Learn More About 1308-1994

Subscribe to our Newsletter

Sign up for our monthly newsletter to learn about new developments, including resources, insights and more.