This guide discusses the importance of failure analysis on cable, joints and terminations used in power systems rated 2.5 kV through 46 kV. Users should review the definitions, and technical papers that are listed in the References and in the Bibliography to gain an understanding of failure analysis issues. Why a cable, joint, or termination fails is an important part of understanding trends and planning for improvements in system reliability.
- Standard Committee
- PE/IC - Insulated Conductors
- Status
- Active PAR
- PAR Approval
- 2020-12-03
- Superseding
- 1511-2004
Working Group Details
- Society
- IEEE Power and Energy Society
- Standard Committee
- PE/IC - Insulated Conductors
- Working Group
-
B12W/P1511_WG - WG for Guide for Investigating and Analyzing Shielded Power Cable Failures on Systems Rated 5 kV Through 46 kV
- IEEE Program Manager
- Dalisa Gonzalez
Contact Dalisa Gonzalez - Working Group Chair
- Kraig Bader
Other Activities From This Working Group
Current projects that have been authorized by the IEEE SA Standards Board to develop a standard.
P1511.1
Guide for Investigating and Analyzing Shielded Power Cable Failures on Systems Rated 2.5 kV Through 46 kV
This guide covers specific methods of failure mode classifications and analysis for shielded power cables rated 2.5 kV through 46 kV.
P1511.2
Guide for Investigating and Analyzing Failures of Joints on Extruded Shielded Power Cables on Systems Rated 5 kV Through 46 kV
This guide covers specific methods of failure mode classifications and analysis for failures of joints on extruded shielded power cables rated 5 kV through 46 kV.
Standards approved by the IEEE SA Standards Board that are within the 10-year lifecycle.
No Active Standards
These standards have been replaced with a revised version of the standard, or by a compilation of the original active standard and all its existing amendments, corrigenda, and errata.
No Superseded Standards
These standards have been removed from active status through a ballot where the standard is made inactive as a consensus decision of a balloting group.
No Inactive-Withdrawn Standards
These standards are removed from active status through an administrative process for standards that have not undergone a revision process within 10 years.
1511.1-2010
IEEE Guide for Investigating and Analyzing Shielded Power Cable Failures on Systems Rated 5 kV Through 46 kV
This guide covers specific methods of failure mode classifications and analysis for shielded power cables rated 5 kV through 46 kV.