IEEE P1142

IEEE Draft Guide for the Selection, Testing, Application and Installation of 300 V to 500 kV Cables Having Radial-Moisture Barriers and/or Longitudinal Water Blocking

This guide provides detailed information relating to the design, testing, application and installation of various types of electrical cables in order to reduce the deleterious effect of moisture and chemical ingress and resultant failures in service. This includes single and multiconductor cables over a complete range of voltage ratings. Testing criteria and installation methods covered along with many technical references.

Standard Committee
PE/IC - Insulated Conductors
Status
Active PAR
PAR Approval
2018-05-14
Superseding
1142-2009

Working Group Details

Society
IEEE Power and Energy Society
Standard Committee
PE/IC - Insulated Conductors
Working Group
A11W/1142_WG - Moisture Impervious Cables Working Group
IEEE Program Manager
Dalisa Gonzalez
Contact Dalisa Gonzalez
Working Group Chair
Kenneth Bow

Other Activities From This Working Group

Current projects that have been authorized by the IEEE SA Standards Board to develop a standard.


No Active Projects

Standards approved by the IEEE SA Standards Board that are within the 10-year lifecycle.


No Active Standards

These standards have been replaced with a revised version of the standard, or by a compilation of the original active standard and all its existing amendments, corrigenda, and errata.


No Superseded Standards

These standards have been removed from active status through a ballot where the standard is made inactive as a consensus decision of a balloting group.


No Inactive-Withdrawn Standards

These standards are removed from active status through an administrative process for standards that have not undergone a revision process within 10 years.


1142-2009
IEEE Guide for the Selection, Testing, Application, and Installation of Cables having Radial-Moisture Barriers and/or Longitudinal Water Blocking

Detailed information relating to the design, testing, application and installation of various types of electrical cables in order to prevent the deleterious effect of moisture and chemical ingress and resultant failures in service is provided in this guide. This includes single and multi-conductor cables over a complete range of voltage ratings. Testing criteria and installation methods covered along with many technical references.

Learn More About 1142-2009