Superseded Standard

IEEE 450-2010

IEEE Recommended Practice for Maintenance, Testing, and Replacement of Vented Lead-Acid Batteries for Stationary Applications

Maintenance, test schedules, and testing procedures that can be used to optimize the life and performance of permanently installed, vented lead-acid storage batteries used for standby service are provided. This recommended practice also provides guidance to determine when batteries should be replaced. This recommended practice is applicable to standby service stationary applications where a charger maintains the battery fully charged and supplies the dc loads.

Standard Committee
PE/ESSB - Energy Storage & Stationary Battery Committee
Status
Superseded Standard
PAR Approval
2010-02-05
Superseded by
450-2020
Superseding
450-2002
Board Approval
2010-12-08
History
ANSI Approved:
2011-09-07
Published:
2011-02-25

Working Group Details

Society
IEEE Power and Energy Society
Standard Committee
PE/ESSB - Energy Storage & Stationary Battery Committee
Working Group
WG_450 - Working Group for Vented Lead Acid Maint and Testing
IEEE Program Manager
Michael Kipness
Contact Michael Kipness
Working Group Chair
Jason Wallis

Other Activities From This Working Group

Current projects that have been authorized by the IEEE SA Standards Board to develop a standard.


No Active Projects

Standards approved by the IEEE SA Standards Board that are within the 10-year lifecycle.


450-2020
IEEE Recommended Practice for Maintenance, Testing, and Replacement of Vented Lead-Acid Batteries for Stationary Applications

Maintenance, test schedules, and testing procedures that can be used to optimize the life and performance of permanently installed, vented lead-acid storage batteries used for standby service are provided. Guidance to determine when batteries should be replaced is also provided. This recommended practice is applicable to standby service stationary applications where a charger maintains the battery fully charged and supplies the dc loads.

Learn More About 450-2020

These standards have been replaced with a revised version of the standard, or by a compilation of the original active standard and all its existing amendments, corrigenda, and errata.


450-2002
IEEE Recommended Practice for Maintenance, Testing , and Replacement of Vented Lead-Acid Batteries for Stationary Applications

Maintenance, test schedules, and testing procedures that can be used to optimize the life and performance of permanently installed, vented lead-acid storage batteries used for standby power applications are provided. This recommended practice also provides guidance to determine when batteries should be replaced. This recommended practice is applicable to full-float stationary applications where a charger maintains the battery fully charged and supplies the dc loads.

Learn More About 450-2002

These standards have been removed from active status through a ballot where the standard is made inactive as a consensus decision of a balloting group.


No Inactive-Withdrawn Standards

These standards are removed from active status through an administrative process for standards that have not undergone a revision process within 10 years.


No Inactive-Reserved Standards
Subscribe to our Newsletter

Sign up for our monthly newsletter to learn about new developments, including resources, insights and more.