Active Standard

IEEE 1106-2015

IEEE Recommended Practice for Installation, Maintenance, Testing, and Replacement of Vented Nickel-Cadmium Batteries for Stationary Applications

This recommended practice provides recommendations for installation design and for installation, maintenance, and testing procedures that can be used to optimize the life and performance of vented nickel-cadmium batteries, including partially recombinant types, used in stationary applications.

Standard Committee
PE/ESSB - Energy Storage & Stationary Battery Committee
Status
Active Standard
PAR Approval
2013-03-06
Superseding
1106-2005
Board Approval
2015-10-26
History
ANSI Approved:
2017-04-06
Published:
2015-11-16

Working Group Details

Society
IEEE Power and Energy Society
Standard Committee
PE/ESSB - Energy Storage & Stationary Battery Committee
Working Group
WG_1106 - Ni-Cd Installation, Maintenance and Testing Working Group
IEEE Program Manager
Michael Kipness
Contact Michael Kipness
Working Group Chair
David Hood

Other Activities From This Working Group

Current projects that have been authorized by the IEEE SA Standards Board to develop a standard.


P1106
Recommended Practice for Installation, Maintenance, Testing, and Replacement of Vented Nickel-Cadmium Batteries for Stationary Applications

This document provides recommendations for installation design and procedures for installation, maintenance, and testing of vented nickel-cadmium batteries (including partially recombinant types) used for standby operation in stationary applications. This recommended practice also provides guidance for determining when these batteries should be replaced. Separate recommendations are provided for renewable energy systems (e.g., wind turbines and photovoltaic systems), which may provide only partial or intermittent charging. Sizing, qualification, and other battery types, including sealed nickel-cadmium, are beyond the scope of this document. This recommended practice does not include any other component of the dc system, nor does it include inspection and testing of the overall dc system. Preoperational and periodic dc system tests of chargers and other dc components may require that the battery be connected to the system. Details for these tests depend on the requirements of the dc system and are beyond the scope of this document.

Learn More About P1106

Standards approved by the IEEE SA Standards Board that are within the 10-year lifecycle.


No Active Standards

These standards have been replaced with a revised version of the standard, or by a compilation of the original active standard and all its existing amendments, corrigenda, and errata.


1106-2005
IEEE Recommended Practice for Installation, Maintenance, Testing, and Replacement of Vented Nickel-Cadmium Batteries for Stationary Applications

This recommended practice provides recommendations for installation design and for installation, maintenance, and testing procedures that can be used to optimize the life and performance of vented nickel-cadmium batteries used in stationary standby applications.

Learn More About 1106-2005

These standards have been removed from active status through a ballot where the standard is made inactive as a consensus decision of a balloting group.


No Inactive-Withdrawn Standards

These standards are removed from active status through an administrative process for standards that have not undergone a revision process within 10 years.


No Inactive-Reserved Standards
Subscribe to our Newsletter

Sign up for our monthly newsletter to learn about new developments, including resources, insights and more.