Project Details
This document provides mathematical models for computer simulation studies of excitation systems and their associated controls for three-phase synchronous generators. The equipment modelled includes the
automatic voltage regulator as well as supplementary controls including reactive current compensation, power system stabilizers, and excitation limiters.
Standards Committee | |
PAR Approval |
2019-02-08
|
PARs |
Additional Resources Details
Historical Base Standard |
Working Group Details
Working Group |
ESCS -WG 421.5 - ESCS - Excitation System Models for Power System Stability Studies Working Group
|
Standards Committee | |
Society | |
IEEE Program Manager | |
Existing Standards |
Excitation system models suitable for use in large-scale system stability studies are
presented. Important limiters and supplementary controls are also included. The model structures presented are intended to facilitate the use of field test data as a means of obtaining model parameters. The models are, however, reduced order models and do not represent all of the control loops on any particular system. The models are valid for frequency deviations of +/-5% from rated frequency and oscillation frequencies up to 3 Hz. These models would not normally be adequate for use in studies of subsynchronous resonance or other shaft torsional interaction problems.
Delayed protective and control features that may come into play in long term dynamic performance studies are not represented. A sample set of data for each of the models, for at least one particular application, is provided.
|
Excitation system and power system stabilizer models suitable for use in large-scale system stability studies are presented. Important excitation limiters and supplementary controls are also included. The model structures presented are intended to facilitate the use of field test data as a means of obtaining model parameters. The models are, however, reduced order models and do not necessarily represent all of the control loops of any particular system. The models are valid for frequency deviations of ?5% from rated frequency and oscillation frequencies up to 3 Hz. These models would not normally be adequate for use in studies of subsynchronous resonance or other shaft torsional interaction behavior. Delayed protective and control features that may come into play in long-term dynamic performance studies are not represented. A sample set of data for each of the models, for at least one particular application, is provided.
|