IEEE 43-2013

IEEE Recommended Practice for Testing Insulation Resistance of Electric Machinery

The dc voltage tests procedures for the measurement of the insulation resistance and polarization index of insulated stator, and rotor windings and how to interpret the results are described in this recommended practice.

Sponsor Committee
PE/EM - Electric Machinery
Learn More About PE/EM - Electric Machinery
Status
Inactive-Reserved Standard
PAR Approval
2010-02-05
Superseding
43-2000
Board Approval
2013-12-11
History
Published:
2014-03-06
Inactivated Date:
2024-03-21

Working Group Details

Society
IEEE Power and Energy Society
Learn More About IEEE Power and Energy Society
Sponsor Committee
PE/EM - Electric Machinery
Learn More About PE/EM - Electric Machinery

Other Activities From This Working Group

Current projects that have been authorized by the IEEE SA Standards Board to develop a standard.


P43
Standard for Testing Insulation Resistance of Electric Machinery

This document describes a procedure for measuring insulation resistance of armature and field windings in rotating machines rated 750 W or greater. It applies to synchronous machines, induction machines, dc machines, and synchronous condensers. It does not apply to fractional-horsepower machines. The document also describes typical insulation resistance characteristics of rotating machine windings and how these characteristics indicate winding condition. It recommends minimum acceptable values of insulation resistance for ac and dc rotating machine windings. Other IEEE standards that include information on insulation resistance measurement are listed in Clause 2.

Learn More About P43

Standards approved by the IEEE SA Standards Board that are within the 10-year lifecycle.


No Active Standards

These standards have been replaced with a revised version of the standard, or by a compilation of the original active standard and all its existing amendments, corrigenda, and errata.


No Superseded Standards

These standards have been removed from active status through a ballot where the standard is made inactive as a consensus decision of a balloting group.


No Inactive-Withdrawn Standards

These standards are removed from active status through an administrative process for standards that have not undergone a revision process within 10 years.


No Inactive-Reserved Standards
Subscribe to our Newsletter

Sign up for our monthly newsletter to learn about new developments, including resources, insights and more.