Superseded Standard

IEEE 11073-10417-2015

IEEE Health informatics -- Personal health device communication Part 10417: Device Specialization -- Glucose Meter

Within the context of the ISO/IEEE 11073 family of standards for device communication, a normative definition of communication between personal telehealth glucose meter devices and compute engines (e.g., cell phones, personal computers, personal health appliances, and set top boxes) is established by this standard in a manner that enables plug-and play interoperability. Appropriate portions of existing standards are leveraged, including ISO/IEEE 11073 terminology, information models, application profile standards, and transport standards. The use of specific term codes, formats, and behaviors in telehealth environments restricting optionality in base frameworks in favor of interoperability are specified. A common core of communication functionality for personal telehealth glucose meters is defined in this standard.

Standard Committee
EMB/11073 - IEEE 11073 Standards Committee
Status
Superseded Standard
PAR Approval
2014-12-10
Superseded by
11073-10417-2023
Superseding
11073-10417-2011
Board Approval
2015-06-11
History
ANSI Approved:
2016-08-25
Published:
2015-07-03

Working Group Details

Society
IEEE Engineering in Medicine and Biology Society
Standard Committee
EMB/11073 - IEEE 11073 Standards Committee
Working Group
PHD - Personal_Health_Device
IEEE Program Manager
Patrycja Jarosz
Contact Patrycja Jarosz
Working Group Chair
Daidi Zhong

Other Activities From This Working Group

Current projects that have been authorized by the IEEE SA Standards Board to develop a standard.


P11073-10426
Health Informatics - Personal Health Device Communication - Device Specialization - Home Healthcare Environment Ventilator

Within the context of the ISO/IEEE 11073 family of standards for device communication, this standard establishes a normative definition of the communication between personal respiratory equipment and managers (e.g. cell phones, personal computers, personal health appliances, set top boxes) in a manner that enables plug-and-play interoperability. It leverages appropriate portions of existing standards including ISO/IEEE 11073 terminology, information models, application profile standards and transport standards. It specifies the use of specific term codes, formats, and behaviors in telehealth environment restricting optionality in base frameworks in favor of interoperability. This standard defines a common core of communication functionality for telehealth in Home Healthcare Environment Ventilator. In this context, the Home Healthcare Environment Ventilator is defined as equipment that provides assistance for patient respiration in the home environment.

Learn More About P11073-10426

P11073-10427
Health Informatics - Device Interoperability - Part 10427: Personal Health Device Communication - Device Specialization - Power Status Monitor of Personal Health Devices

This standard specifies a normative definition of communication between devices containing a power source (agents) and managers (e.g., cell phones, personal computers, personal health appliances, set-top boxes) in a manner that enables plug-and-play interoperability. Using existing terminology, information profiles, application profile standards, and transport standards as defined in other ISO/IEEE 11073 standards, this standard defines a common core of communication functionality of personal health devices (PHDs) containing a battery, including: 1) Current device power status ( e.g., for instance on mains or on battery); 2) Battery charge status and prediction (for instance percent of full charge, expected remaining lifetime of battery); and 3) Estimated battery run- time remaining (for instance, minutes) ; 4) Support for battery lifetime simulation.

Learn More About P11073-10427

P11073-10441
IEEE Draft Standard - Health Informatics--Personal health device communication Part 10441: Device specialization--Cardiovascular fitness and activity monitor

Within the context of the ISO/IEEE 11073 family of standards for device communication, a normative definition of communication between personal telehealth cardiovascular fitness and activity monitor devices and managers (e.g., cell phones, personal computers, personal health appliances, and set top boxes) is established in this standard in a manner that enables plug-and-play interoperability. Appropriate portions of existing standards are leveraged including ISO/IEEE 11073 terminology, information models, application profile standards, and transport standards. The use of specific term codes, formats, and behaviors in telehealth environments restricting optionality in base frameworks in favor of interoperability is specified. A common core of communication functionality for personal telehealth cardiovascular fitness and activity monitor devices is defined in this standard.

Learn More About P11073-10441

P11073-20601
Health Informatics - Device Interoperability - Part 20601: Personal Health Device Communication - Application Profile - Optimized Exchange Protocol

Within the context of the ISO/IEEE 11073 personal health device standard family, this standard defines an optimized exchange protocol and modeling techniques to be used by implementers of personal health devices to create interoperability between device types and vendors. This standard establishes a common framework for an abstract model of personal health data available in a transport-independent transfer syntax required to establish logical connections between systems and to provide presentation capabilities and services needed to perform communication tasks. The protocol is optimized to personal health usage requirements and leverages commonly used methods and tools wherever possible.

Learn More About P11073-20601

Standards approved by the IEEE SA Standards Board that are within the 10-year lifecycle.


No Active Standards

These standards have been replaced with a revised version of the standard, or by a compilation of the original active standard and all its existing amendments, corrigenda, and errata.


No Superseded Standards

These standards have been removed from active status through a ballot where the standard is made inactive as a consensus decision of a balloting group.


No Inactive-Withdrawn Standards

These standards are removed from active status through an administrative process for standards that have not undergone a revision process within 10 years.


No Inactive-Reserved Standards
Subscribe to our Newsletter

Sign up for our monthly newsletter to learn about new developments, including resources, insights and more.