Project Details
This recommended practice provides procedures and test voltage values for acceptance and maintenance testing of Electric Submersible Pump (ESP) cable systems. The recommended practice also covers installation and handling practices. This procedure applies to cable systems rated 3 kV to 8 kV (phase to phase).
Standards Committee | |
PAR Approval |
2020-09-24
|
PARs |
Additional Resources Details
Historical Base Standard |
Working Group Details
Working Group |
Downhole Cable WG - Downhole Cable Working Group
|
Standards Committee | |
Society | |
IEEE Program Manager | |
Active Projects |
This recommended practice establishes recommendations for three-conductor round and flat oil-well cables used in supplying three-phase ac electric power to submersible pump motors. The three major cables by components are as follows:
a) Cables with copper conductors, ethylene-propylene diene monomer (EPDM) insulation, nitrile
jacket, and metallic armor
b) Cables with copper conductors, EPDM insulation, EPDM jacket, and metallic armor
c) Cables with copper conductors, EPDM insulation, lead sheath, and metallic armor
|
This recommended practice establishes requirements for three-conductor round-and-flat-type oil-well cable used in supplying three-phase ac electric power to submersible pump motors. The major cable components are copper conductors, polypropylene insulation, polymeric jacket, and galvanized metallic armor.
|
|
Existing Standards |
Procedures and test voltage values for acceptance and maintenance testing of electrical submersible pump (ESP) cable systems are presented. This recommended practice applies to cable systems rated 3 kV and 5 kV (phase to phase) and is intended only for this special-purpose cable. The intent is to provide uniform test procedures and guidelines for evaluation of the test results.
|
Minimum requirements for the construction, manufacturing, purchasing, and application of electric submersible pump cable are presented. The cable is round or flat, with ethylene? propylene rubber insulation, nitrile jacket, ethylene?propylene diene monomer (EPDM) jacket or lead sheath, and armor. These cables are for voltages not exceeding 3 kV or 5 kV (phase to phase) and conductor temperatures not exceeding 140 ?C (284 ?F) for nitrile or a maximum of 204 ?C (400 ?F) for EPDM jacket or lead sheath cable. Conductors, insulation, barrier (optional), assembly and jacket, armor, requirements for testing by the manufacturer, and cable ampacity are covered.
|
|
Minimum requirements for the construction, manufacturing, purchasing, and application of electric submersible pump cable are presented. The cable is round or flat, with polypropylene rubber insulation, nitrile jacket, and armor. These cables are for voltages not exceeding 3 kV or 5 kV (phase to phase) and conductor temperatures not exceeding 96 ?C (205 ?F) for nitrile or a maximum of ?10 ?C (14 ?F). Conductors, insulation, assembly and jacket, armor, requirements for testing by the manufacturer, and cable ampacity are covered.
|
|
Procedures and test voltage values for acceptance and maintenance testing of electric submersible pump (ESP) cable systems are presented. This recommended practice applies to cable systems rated 3 kV and 5 kV (phase to phase) and is intended only for this special-purpose cable. The intent is to provide uniform test procedures and guidelines for evaluation of the test results.
|
|
Minimum requirements for the design, construction, manufacturing, testing, purchasing, and application of electric submersible pump (ESP) cable are presented. The cable is round or flat, with ethylene?propylene rubber insulation, nitrile jacket, ethylene?propylene diene monomer (EPDM) jacket or lead sheath, and armor. These cables are for voltages not exceeding 3 kV or 5 kV (phase to phase) and conductor temperatures not exceeding 140 ?C (284 ?F) for nitrile or a maximum of 232 ?C (450 ?F) for EPDM jacket or lead sheath cable. Conductors, insulation, barrier (optional), assembly with or without jacket, armor, requirements for testing by the manufacturer, and cable ampacity are all covered in the document.
|
|
Minimum requirements for the design, construction, manufacturing, testing, purchasing, and application of electric submersible pump cable are presented. The cable is round or flat, with polypropylene rubber insulation, nitrile or polyethylene jacket, and armor. These cables are for voltages not exceeding 3 kV or 5 kV (phase to phase) and conductor temperatures not exceeding 96 ?C (205 ?F) maximum for nitrile or a maximum minimum of ?10 ?C (14 ?F) minimum. Conductors, insulation, assembly and with or without jacket, armor, requirements for testing by the manufacturer, and cable ampacity are all covered in the document.
|