Conformance tests and requirements for the coating integrity of carbon steel polemounted enclosures containing apparatus energized in excess of 600 V, typically located out of reach of the general public, including, but not limited to, the following types of equipment enclosures: pole-mounted distribution transformers, pole-mounted switches, pole-mounted regulators, pole-mounted metering equipment, pole-mounted reclosers, and pole-mounted switchgear, are covered.
Sponsor Committee | |
Status |
Active
|
Corrigendum | |
Board Approval |
2010-06-17
|
History |
Published Date:2010-09-20
|
Additional Resources Details
Pars | |
Historical Base Standard |
Working Group Details
Working Group |
Dist-WGC57.12.31 - Distribution - Encl Integrity - Pole Mtd. Working Group
|
Working Group Chair |
Daniel Mulkey
|
Sponsor Committee | |
Society | |
IEEE Program Manager | |
Active Projects |
This standard covers conformance tests and requirements for the enclosure integrity of pole-mounted equipment for installations in coastal environments, containing apparatus energized in excess of 600 V, typically not accessible to the general public, such as but not limited to the following types of equipment:
a) Pole-mounted distribution transformers
b) Pole-mounted switches
c) Pole-mounted regulators
d) Pole-mounted metering equipment
e) Pole-mounted reclosers/sectionalizers
f) Pole-mounted capacitors
|
This standard covers conformance tests and requirements for the enclosure integrity of pole-mounted equipment containing apparatus energized in excess of 600 V, typically not accessible to the general public, such as but not limited to the following types of equipment:
a) Pole-mounted distribution transformers
b) Pole-mounted switches
c) Pole-mounted regulators
d) Pole-mounted metering equipment
e) Pole-mounted reclosers/sectionalizers
f) Pole-mounted capacitors
|
|
Existing Standards |
Conformance tests and requirements for the coating integrity of carbon steel pole mounted enclosures containing apparatus energized in excess of 600 volts, typically located out of reach of the general public, including, but not limited to, the following types of equipment enclosures: polemounted distribution transformers, pole-mounted switches, pole-mounted regulators, pole-mounted metering equipment, pole-mounted reclosers, and pole-mounted switchgear are covered.
|
Conformance tests and requirements for the coating integrity of pole-mounted enclosures for application in coastal environments containing apparatus energized in excess of 600 V, typically located out of reach of the general public, including, but not limited to, the following types of equipment enclosures: pole-mounted distribution transformers, pole-mounted switches, pole-mounted regulators, pole-mounted metering equipment, pole-mounted reclosers, and pole-mounted switchgear, are discussed.
|
|