Recommendations regarding mineral oil tests and evaluation procedures are made in this guide; references are made to methods of reconditioning and reclaiming conventional petroleum (mineral) dielectric insulating liquids; the levels at which these methods become necessary; and the routines for restoring oxidation resistance, where required, by the addition of oxidation inhibitors. The intent is to assist the power equipment operator in evaluating the serviceability of mineral oil received in equipment, oil as received from the supplier for filling new equipment at the installation site, and oil as processed into such equipment; and to assist the operator in maintaining mineral oil in serviceable condition. The mineral oil covered is used in transformers, reactors, load tap changers, and voltage regulators.
- Standard Committee
- PE/TR - Transformers
- Status
- Active Standard
- PAR Approval
- 2011-11-09
- Superseding
- C57.106-2006
- Board Approval
- 2015-12-05
- History
-
- ANSI Approved:
- 2017-05-31
- Published:
- 2016-03-23
Working Group Details
- Society
- IEEE Power and Energy Society
- Standard Committee
- PE/TR - Transformers
- Working Group
-
WGC57.106 - Insulating Fluids - Mineral Oil Working Group
- IEEE Program Manager
- Patrycja Jarosz
Contact Patrycja Jarosz - Working Group Chair
- Robert Rasor
Other Activities From This Working Group
Current projects that have been authorized by the IEEE SA Standards Board to develop a standard.
No Active Projects
Standards approved by the IEEE SA Standards Board that are within the 10-year lifecycle.
No Active Standards
These standards have been replaced with a revised version of the standard, or by a compilation of the original active standard and all its existing amendments, corrigenda, and errata.
C57.106-1977
IEEE Guide for Acceptance and Maintenance of Insulating Oil in Equipment
Recommendations are made regarding oil tests and evaluation procedures; methods of reconditioning and reclaiming conventional petroleum (mineral) dielectric oils; the levels at which these methods become necessary; and the routines for restoring oxidation resistance, where required, by the addition of inhibitors. The intent is to assist the power equipment operator in evaluating the serviceability of oil received in equipment, oil as received from the refiner for filling new equipment at the installation site, and oil as processed into such equipment; and to assist the operator in maintaining his oil in serviceable condition. The mineral oil covered is used in transformers, switchgear, reactors, and current breakers.
C57.106-1991
IEEE Guide for Acceptance and Maintenance of Insulating Oil in Equipment
SUPERSEDED BY IEEE STC C57.106-2002 (SH/SS95008) NOT AVAILABLE TO RESELLERS This IEEE Standards product is part of the C57 family on Power Distribution and Regulating Transformers.
C57.106-2002
Guide for Acceptance and Maintenance of Insulating Oil in Equipment
Recommendations regarding oil tests and evaluation procedures are made in this guide;references are made to methods of reconditioning and reclaiming conventional petroleum (mineral) dielectric insulating oils;the levels at which these methods become necessary; and the routines for restoring oxidation resistance, where required, by the addition of oxidation inhibitors. The intent is to assist the power equipment operator in evaluating the serviceability of oil received in equipment, oil as received from the supplier for filling new equipment at the installation site, and oil as processed into such equipment; and to assist the operator in maintaining oil in serviceable condition. The mineral oil covered is used in transformers, reactors, circuit breakers, load tap changers, and voltage regulators.
C57.106-2006
IEEE Guide for Acceptance and Maintenance of Insulating Oil in Equipment
Recommendations regarding oil tests and evaluation procedures are made in this guide; references are made to methods of reconditioning and reclaiming conventional petroleum (mineral) dielectric insulating oils; the levels at which these methods become necessary; and the routines for restoring oxidation resistance, where required, by the addition of oxidation inhibitors. The intent is to assist the power equipment operator in evaluating the serviceability of oil received in equipment, oil as received from the supplier for filling new equipment at the installation site, and oil as processed into such equipment; and to assist the operator in maintaining oil in serviceable condition. The mineral oil covered is used in transformers, reactors, circuit breakers, load tap changers, and voltage regulators. Remarks: Revision of IEEE Std C57.106-2002
These standards have been removed from active status through a ballot where the standard is made inactive as a consensus decision of a balloting group.
No Inactive-Withdrawn Standards
These standards are removed from active status through an administrative process for standards that have not undergone a revision process within 10 years.
No Inactive-Reserved Standards