Superseded Standard

IEEE C37.016-2006

IEEE Standard for AC High Voltage Circuit Switchers rated 15.5kV through 245kV

This Standard is applicable to AC circuit switchers designed for outdoor installation and for rated power frequencies of 50 and 60 Hz and rated maximum voltages of 15.5 kV through 245 kV. It is only applicable to three-pole circuit switchers for use in three-phase systems. This Standard is also applicable to the operating devices of circuit switchers and to their auxiliary equipment.

Sponsor Committee
PE/SWG - Switchgear
Learn More About PE/SWG - Switchgear
Status
Superseded Standard
PAR Approval
2006-09-15
Superseded by
C37.016-2018
Board Approval
2006-12-06
History
ANSI Approved:
2007-04-23
Published:
2007-06-06

Working Group Details

Society
IEEE Power and Energy Society
Learn More About IEEE Power and Energy Society
Sponsor Committee
PE/SWG - Switchgear
Learn More About PE/SWG - Switchgear
Working Group
HVCB/C37.016 - C37.016 - Standard for AC High Voltage Circuit Switchers Rated 15.5 kV through 245 kV
IEEE Program Manager
Jennifer Santulli
Contact Jennifer Santulli
Working Group Chair
Neil Mc Cord

Other Activities From This Working Group

Current projects that have been authorized by the IEEE SA Standards Board to develop a standard.


PC37.016

Standard for AC High Voltage Circuit Switchers Rated 15.5 kV through 245 kV

This standard specifies the basis of rating, preferred ratings, and test procedures for ac circuit switchers, which are designed for outdoor installation and for rated power frequencies of 50 Hz and 60 Hz and rated maximum voltages of 15.5 kV through 245 kV. The standard applies only to three-pole circuit switchers for use in three-phase systems. This standard also applies to the operating devices of circuit switchers and to their auxiliary equipment.

Learn More About PC37.016

Standards approved by the IEEE SA Standards Board that are within the 10-year lifecycle.


C37.016-2018

IEEE Standard for AC High Voltage Circuit Switchers Rated 15.5 kV through 245 kV

This standard is applicable to ac circuit switchers designed for outdoor installation and for rated power frequencies of 50 Hz and 60 Hz and rated maximum voltages of 15.5 kV through 245 kV. It is applicable only to three-pole circuit switchers for use in three-phase systems. This standard is also applicable to the operating devices of circuit switchers and to their auxiliary equipment. Included in this document are the normal and special service conditions under which the ratings are based and requirements for design and construction, which include those for interrupting media, stored energy systems, operating characteristics, mechanical loading and operation capabilities, electrical insulation, and auxiliary devices. The rating structure establishes the basis for all assigned ratings, including continuous current, dielectric withstand voltages, primary-bus fault breaking current, transformer-limited fault breaking current, short-circuit making current, transient recovery voltages, and capacitor switching, plus associated capabilities such as mechanical endurance and operation under high- and low-temperature environmental extremes. Routine (production) tests are defined and requirements for their execution documented.

Learn More About C37.016-2018

C37.016-2018/Cor 1-2021

IEEE Standard for AC High Voltage Circuit Switchers 15.5 kV through 245 kV - Corrigendum 1

This corrigendum is to improve the current IEEE Std C37.016.

Learn More About C37.016-2018/Cor 1-2021

These standards have been replaced with a revised version of the standard, or by a compilation of the original active standard and all its existing amendments, corrigenda, and errata.


No Superseded Standards

These standards have been removed from active status through a ballot where the standard is made inactive as a consensus decision of a balloting group.


No Inactive-Withdrawn Standards

These standards are removed from active status through an administrative process for standards that have not undergone a revision process within 10 years.


No Inactive-Reserved Standards
Subscribe to our Newsletter

Sign up for our monthly newsletter to learn about new developments, including resources, insights and more.