Active Standard

IEEE/IEC 62704-1-2017

IEC/IEEE International Standard for Determining the Peak Spatial Average Specific Absorption Rate (SAR) in the Human Body from Wireless Communications Devices, 30 MHz - 6 GHz. Part 1: General Requirements for using the Finite Difference Time Domain (FDTD) Method for SAR Calculations

The scope of this standard is to define the methodology for the application of the finite difference time domain (FDTD) technique when used for determining the peak spatial-average specific absorption rate (SAR) in the human body exposed to wireless communication devices with known uncertainty. It defines methods to validate the numerical model of the device under test (DUT) and to assess its uncertainty when used in SAR simulations. Moreover, it defines procedures to determine the peak spatial average SAR in a cubical volume and to validate the correct implementation of the FDTD simulation software. This document will not recommend specific SAR limits since these are found elsewhere, e.g., in the guidelines published by the International Commission on Non-Ionizing Radiation Protection (ICNIRP) or in IEEE C95.1.

Sponsor Committee
BOG/ICES - International Committee on Electromagnetic Safety
Learn More About BOG/ICES - International Committee on Electromagnetic Safety
Status
Active Standard
PAR Approval
2013-08-23
Board Approval
2017-09-28
History
Published:
2017-10-27

Working Group Details

Society
IEEE SA Board of Governors
Sponsor Committee
BOG/ICES - International Committee on Electromagnetic Safety
Learn More About BOG/ICES - International Committee on Electromagnetic Safety
Working Group
SC2 - TC34 Subcommittee 2
IEEE Program Manager
Patricia Roder
Contact Patricia Roder
Working Group Chair
jafar keshvari

Other Activities From This Working Group

Current projects that have been authorized by the IEEE SA Standards Board to develop a standard.


No Active Projects

Standards approved by the IEEE SA Standards Board that are within the 10-year lifecycle.


62704-2-2017
IEEE/IEC International Standard -- Determining the peak spatial-average specific absorption rate (SAR) in the human body from wireless communications devices, 30 MHz to 6 GHz -- Part 2: Specific requirements for finite difference time domain (FDTD) modelling of exposure from vehicle mounted antennas

This part of IEC/IEEE 62704 establishes the concepts, techniques, validation procedures, uncertainties and limitations of the finite difference time domain technique (FDTD) when used for determining the peak spatial-average and whole-body average specific absorption rate (SAR) in a standardized human anatomical model exposed to the electromagnetic field emitted by vehicle mounted antennas in the frequency range from 30 MHz to 1 GHz, which covers typical high power mobile radio products and applications. This document specifies and provides the test vehicle, human body models and the general benchmark data for those models. It defines antenna locations, operating configurations, exposure conditions, and positions that are typical of persons exposed to the fields generated by vehicle mounted antennas. The extended frequency range up to 6 GHz will be considered in future revisions of this document. This document does not recommend specific peak spatial-average and whole-body average SAR limits since these are found in other documents, e.g. IEEE C95.1-2005, ICNIRP (1998).

Learn More About 62704-2-2017

62704-3-2017
Determining the Peak Spatial-Average Specific Absorption Rate (SAR) in the Human Body from Wireless Communications Devices, 30 MHz - 6 GHz Part 3: Specific Requirements for Using the Finite Difference Time Domain (FDTD) Method for SAR Calculations of Mobile Phones

The project defines the concepts, techniques, benchmark phone models, validation procedures, uncertainties and limitations of the finite difference time domain (FDTD) technique when used for determining the peak spatial-average specific absorption rate (SAR) in standardized head and body phantoms exposed to the electromagnetic fields generated by wireless communication devices, in particular pre-compliance assessment of mobile phones, in the frequency range from 30 MHz to 6 GHz. It recommends and provides guidance on the numerical modelling of mobile phones and benchmark results to verify the general approach for the numerical simulations of such devices. It defines acceptable modeling requirements, guidance on meshing and test positions of the mobile phone and the phantom models. This document does not recommend specific SAR limits since these are found in other documents, e.g., IEEE C95.1-2005 and ICNIRP.

Learn More About 62704-3-2017

62704-4-2020
IEC/IEEE International Standard - Determining the peak spatial-average specific absorption rate (SAR) in the human body from wireless communication devices, 30 MHz to 6 GHz - Part 4: General requirements for using the finite element method for SAR calculations

This part of IEC/IEEE 62704 describes the concepts, techniques, and limitations of the finite element method (FEM) and specifies models and procedures for verification, validation and uncertainty assessment for the FEM when used for determining the peak spatial-average specific absorption rate (psSAR) in phantoms or anatomical models. It recommends and provides guidance on the modelling of wireless communication devices, and provides benchmark data for simulating the SAR in such phantoms or models. This document does not recommend specific SAR limits because these are found elsewhere (e.g. in IEEE Std C95.1 [1]1 or in the guidelines published by the International Commission on Non-Ionizing Radiation Protection (ICNIRP) [2]).

Learn More About 62704-4-2020

These standards have been replaced with a revised version of the standard, or by a compilation of the original active standard and all its existing amendments, corrigenda, and errata.


No Superseded Standards

These standards have been removed from active status through a ballot where the standard is made inactive as a consensus decision of a balloting group.


No Inactive-Withdrawn Standards

These standards are removed from active status through an administrative process for standards that have not undergone a revision process within 10 years.


No Inactive-Reserved Standards
Subscribe to our Newsletter

Sign up for our monthly newsletter to learn about new developments, including resources, insights and more.