The recommended practices and procedures for direct voltage acceptance and maintenance testing of shielded, laminated, dielectric-insulated power cable systems rated 5 kV to 500 kV are presented in this guide. It applies to all types of laminated power cable systems such as paper insulated, lead covered, pipe-type, and pressurized cables that are intended for the transmission or distribution of ac electric power. The tabulated test levels assume that the cable systems have an effectively grounded neutral system or a grounded metallic shield.
- Sponsor Committee
- PE/IC - Insulated Conductors
- Status
- Active Standard
- PAR Approval
- 2017-02-17
- Superseding
- 400.1-2007
- Board Approval
- 2018-12-05
- History
-
- Published:
- 2019-01-31
Working Group Details
- Society
- IEEE Power and Energy Society
- Sponsor Committee
- PE/IC - Insulated Conductors
- Working Group
-
F02W/P400.1_WG - Guide for Shielded Power Cable Systems
- IEEE Program Manager
- Dalisa Gonzalez
Contact Dalisa Gonzalez - Working Group Chair
- William Larzelere
Other Activities From This Working Group
Current projects that have been authorized by the IEEE SA Standards Board to develop a standard.
No Active Projects
Standards approved by the IEEE SA Standards Board that are within the 10-year lifecycle.
No Active Standards
These standards have been replaced with a revised version of the standard, or by a compilation of the original active standard and all its existing amendments, corrigenda, and errata.
400.1-2007
IEEE Guide for Field Testing of Laminated Dielectric, Shielded Power Cable Systems Rated 5 kV and Above with High Direct Current Voltage
The recommended practices and procedures for acceptance and maintenance testing of shielded, laminated dielectric insulated power cable systems 5 kV and above are presented.
532-2007
IEEE Guide for Selecting and Testing Jackets for Power, Instrumentation, and Control Cables
Revision of IEEE Std 532-1993. This guide covers properties of commonly used jackets as well as selection and testing of jackets. It is written for those responsible for optimizing cable designs. The purpose is to present a reasonably complete picture of the role of jackets so that the subject can be approached in an orderly and organized manner. An effort has been made to avoid the highly technical language and theory commonly used by electrical engineers and chemists to discuss the more detailed application of jackets.
These standards have been removed from active status through a ballot where the standard is made inactive as a consensus decision of a balloting group.
No Inactive-Withdrawn Standards
These standards are removed from active status through an administrative process for standards that have not undergone a revision process within 10 years.
No Inactive-Reserved Standards