Active Standard

IEEE 1547a-2020

IEEE Standard for Interconnection and Interoperability of Distributed Energy Resources with Associated Electric Power Systems Interfaces--Amendment 1: To Provide More Flexibility for Adoption of Abnormal Operating Performance Category III

The performance and functional capability requirements for DER connected with the Area Electric Power Systems (Area EPS) are defined in IEEE Std 1547(TM). This amendment revises the ranges of allowable trip clearing time settings in Table 13 for DERs in abnormal operating performance category III to allow wider ranges that can broaden and simplify the adoption of the standard. In addition, the related informative Figure H.9 is revised accordingly.

Sponsor Committee
BOG/SC21 - Distributed Generation, Energy Storage and Interoperability Standards Committee
Learn More About BOG/SC21 - Distributed Generation, Energy Storage and Interoperability Standards Committee
Status
Active Standard
PAR Approval
2019-09-05
Board Approval
2020-03-09
History
Published:
2020-04-15

Working Group Details

Society
IEEE SA Board of Governors
Sponsor Committee
BOG/SC21 - Distributed Generation, Energy Storage and Interoperability Standards Committee
Learn More About BOG/SC21 - Distributed Generation, Energy Storage and Interoperability Standards Committee
Working Group
1547_revwg - 1547 Revision Working Group
IEEE Program Manager
Malia Zaman
Contact Malia Zaman
Working Group Chair
Mamadou Diong

Other Activities From This Working Group

Current projects that have been authorized by the IEEE SA Standards Board to develop a standard.


P1547
Standard for Interconnection and Interoperability of Distributed Energy Resources with Associated Electric Power Systems Interfaces

This standard establishes criteria and requirements for interconnection of distributed energy resources (DER) with electric power systems (EPS) and associated interfaces. The standard includes general interconnection technical specifications and performance requirements, reactive power capability and voltage/power control requirements, response to Area EPS abnormal conditions, power quality, islanding, DER on distribution secondary grid/area/street (grid) networks and spot networks, interoperability, information exchange, information models and protocols, test and verification requirements. This revision incorporates updates from previous errata, one previous amendment and also includes updates to requirements based on industry feedback.

Learn More About P1547

Standards approved by the IEEE SA Standards Board that are within the 10-year lifecycle.


1547-2018
IEEE Standard for Interconnection and Interoperability of Distributed Energy Resources with Associated Electric Power Systems Interfaces

The technical specifications for, and testing of, the interconnection and interoperability between utility electric power systems (EPSs) and distributed energy resources (DERs) are the focus of this standard. It provides requirements relevant to the performance, operation, testing, safety considerations, and maintenance of the interconnection. It also includes general requirements, response to abnormal conditions, power quality, islanding, and test specifications and requirements for design, production, installation evaluation, commissioning, and periodic tests. The stated requirements are universally needed for interconnection of DER, including synchronous machines, induction machines, or power inverters/converters and will be sufficient for most installations. The criteria and requirements are applicable to all DER technologies interconnected to EPSs at typical primary and/or secondary distribution voltages. Installation of DER on radial primary and secondary distribution systems is the main emphasis of this document, although installation of DERs on primary and secondary network distribution systems is considered. This standard is written considering that the DER is a 60 Hz source.

Learn More About 1547-2018

These standards have been replaced with a revised version of the standard, or by a compilation of the original active standard and all its existing amendments, corrigenda, and errata.


No Superseded Standards

These standards have been removed from active status through a ballot where the standard is made inactive as a consensus decision of a balloting group.


No Inactive-Withdrawn Standards

These standards are removed from active status through an administrative process for standards that have not undergone a revision process within 10 years.


No Inactive-Reserved Standards
Subscribe to our Newsletter

Sign up for our monthly newsletter to learn about new developments, including resources, insights and more.