A review of the nature of partial discharge in machine windings, how it can be measured under both off-line and on-line conditions, how it can be measured for individual form wound coils or bars, and the significance and limitations of the measured values are covered in this standard.
- Sponsor Committee
- PE/EM - Electric Machinery
Learn More About PE/EM - Electric Machinery - Joint Sponsors
-
DEI/SC
- Status
- Active Standard
- PAR Approval
- 2010-12-08
- Superseding
- 1434-2000
- Board Approval
- 2014-11-03
- History
-
- Published:
- 2014-12-04
Working Group Details
- Society
- IEEE Power and Energy Society
Learn More About IEEE Power and Energy Society - Sponsor Committee
- PE/EM - Electric Machinery
Learn More About PE/EM - Electric Machinery - Working Group
-
Matl - WG1434 - Materials SC - Measurement of Partial Discharges in AC Electric Machinery
- IEEE Program Manager
- Malia Zaman
Contact Malia Zaman - Working Group Chair
- Hugh Zhu
Other Activities From This Working Group
Current projects that have been authorized by the IEEE SA Standards Board to develop a standard.
P1434
Guide for the Measurement of Partial Discharges in AC Electric Machinery
This guide discusses both on-line and off-line partial discharge (PD) measurements on complete windings of any type, as well as measurements on individual form-wound coils and bars. Measurements selected from those that are outlined may be appropriate for application during the manufacture, installation, operation, and maintenance of windings of ac electric machinery.
Standards approved by the IEEE SA Standards Board that are within the 10-year lifecycle.
No Active Standards
These standards have been replaced with a revised version of the standard, or by a compilation of the original active standard and all its existing amendments, corrigenda, and errata.
1434-2000
IEEE Guide to the Measurement of Partial Discharges in Rotating Machinery
A review of the nature of partial discharge in machine windings, how it can be measured under both off-line and on-line conditions, how it can be measured for individual form-wound coils or bars, and the significance and limitations of the measured values are covered.
These standards have been removed from active status through a ballot where the standard is made inactive as a consensus decision of a balloting group.
No Inactive-Withdrawn Standards
These standards are removed from active status through an administrative process for standards that have not undergone a revision process within 10 years.
No Inactive-Reserved Standards