IEEE 1349-2011

IEEE Guide for Application of Electric Motors in Class I, Division 2 and Class I, Zone 2 Hazardous (Classified) Locations

Three-phase and single-phase AC synchronous and induction electric motors in ratings 0.18 kW (1/4 hp) and larger are covered in this guide. Primary emphasis is on the use of open or non-explosion proof or non-flame proof enclosed motors in Class I, Division 2 and Class I, Zone 2 locations as covered in NFPA 70-2011. Surface temperature test methods and sine wave and non-sine wave applications are covered. Precautions against excessive surface temperatures and sparking are included. To mitigate hot surface temperatures and sparking, this document provides guidance for selecting, operating, and maintaining motors in Class I, Division 2 and Class I, Zone 2 locations. This guide does not cover AC wound rotor motors and DC electric motors. Motors installed in locations other than Class I, Division 2 and Class I, Zone 2 as covered in NFPA 70-2011 are not covered in this guide. This document is not a specification and is not intended to be used as a specification for purchasing motors. The voltage breaks in this document are 1000 V and less, and over 1000 V.

Standard Committee
IAS/PCI - Petroleum and Chemical Industry
Status
Superseded Standard
PAR Approval
2010-12-08
Superseded by
1349-2021
Superseding
1349-2001
Board Approval
2011-09-10
History
ANSI Approved:
2012-12-03
Published:
2011-12-09

Working Group Details

Society
IEEE Industry Applications Society
Standard Committee
IAS/PCI - Petroleum and Chemical Industry
Working Group
1349_WG - Machines in Hazardous Locations Working Group
IEEE Program Manager
Michael Kipness
Contact Michael Kipness
Working Group Chair
Lorraine Padden

Other Activities From This Working Group

Current projects that have been authorized by the IEEE SA Standards Board to develop a standard.


No Active Projects

Standards approved by the IEEE SA Standards Board that are within the 10-year lifecycle.


1349-2021
IEEE Guide for the Application of Electric Machines in Zone 2 and Class I, Division 2 Hazardous (Classified) Locations

Three-phase and single-phase ac synchronous and induction electric machines in ratings 0.18 kW (1/4 hp) and larger are covered in this guide. Primary emphasis is on the use of open or non-explosion proof or non-flame proof enclosed machines in Zone 2 and Class I, Division 2 locations as covered in the NEC(R) (NFPA 70-2020) and CE Code(R) (CSA C22.1-2021) as applicable. Surface temperature test methods and sine wave and non-sine wave applications are covered. Precautions against excessive surface temperatures and sparking are included. To help mitigate hot surface temperatures and sparking, this document provides guidance for selecting, operating, and maintaining machines in Zone 2 and Class I, Division 2 locations. This guide does not cover ac wound rotor machines and dc electric machines. Machines installed in locations other than Zone 2 and Class I, Division 2 as covered in NFPA 70-2020 or CSA C22.1-2021 are not covered in this guide. This document is not a specification and is not intended to be used as a specification for purchasing electric machines. The voltage breaks in this document are 1000 V and less, and over 1000 V. (Additional documents for this standard can be downloaded at https://standards.ieee.org/content/dam/ieee-standards/standards/web/download/1349-2021_downloads.zip)

Learn More About 1349-2021

1349-2021/Cor 1-2022
IEEE Guide for the Application of Electric Machines in Zone 2 and Class I, Division 2 Hazardous (Classified) Locations - Corrigendum 1

The technical error in the requirements on the space heater test method (8.3.2) is corrected by this corrigendum.

Learn More About 1349-2021/Cor 1-2022

These standards have been replaced with a revised version of the standard, or by a compilation of the original active standard and all its existing amendments, corrigenda, and errata.


No Superseded Standards

These standards have been removed from active status through a ballot where the standard is made inactive as a consensus decision of a balloting group.


No Inactive-Withdrawn Standards

These standards are removed from active status through an administrative process for standards that have not undergone a revision process within 10 years.


No Inactive-Reserved Standards
Subscribe to our Newsletter

Sign up for our monthly newsletter to learn about new developments, including resources, insights and more.